• 96-Well 0.2ml PCR Plates, Non-Sterile, Half-Skirted, Dnase & Rnase Free, Clear,
  • 96-Well 0.2ml PCR Plates, Non-Sterile, Half-Skirted, Dnase & Rnase Free, Clear,
  • 96-Well 0.2ml PCR Plates, Non-Sterile, Half-Skirted, Dnase & Rnase Free, Clear,
  • 96-Well 0.2ml PCR Plates, Non-Sterile, Half-Skirted, Dnase & Rnase Free, Clear,
  • 96-Well 0.2ml PCR Plates, Non-Sterile, Half-Skirted, Dnase & Rnase Free, Clear,
  • 96-Well 0.2ml PCR Plates, Non-Sterile, Half-Skirted, Dnase & Rnase Free, Clear,

96-Well 0.2ml PCR Plates, Non-Sterile, Half-Skirted, Dnase & Rnase Free, Clear,

Disposable: Disposable
Certification: CE, ISO, FDA
Material: PP Material
Skirt: Half-Skirted
Temperature Range: -20ºC to 100ºC
Rcf: 6000
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
96-well
Sterile
Dnase, Rnase, and Endotoxin Free
Color
Clear Pink Green Blue Yellow
Transport Package
25/Pack, 100/Case
Specification
96-well
Trademark
Biologix
Origin
China
HS Code
3917220000
Production Capacity
500 Cases/Week

Product Description

Bioplastics Transparent  Pcr Plates PCR Plates 0.2ml 96 Well PCR Plate With Half-Skirted DNase & RNase Free For Laboratory
  
96-Well 0.2ml PCR Plates, Non-Sterile, Half-Skirted, Dnase & Rnase Free, Clear,
96-Well 0.2ml PCR Plates, Non-Sterile, Half-Skirted, Dnase & Rnase Free, Clear,
96-Well 0.2ml PCR Plates, Non-Sterile, Half-Skirted, Dnase & Rnase Free, Clear,
 
96-Well 0.2ml PCR Plates, Non-Sterile, Half-Skirted, Dnase & Rnase Free, Clear,
96-Well 0.2ml PCR Plates, Non-Sterile, Half-Skirted, Dnase & Rnase Free, Clear,
96-Well 0.2ml PCR Plates, Non-Sterile, Half-Skirted, Dnase & Rnase Free, Clear,

I. APPLICATIONS
1. Molecular biology
2. Cell centrifugation
3. Sample storage
4. Centrifugation of precipitates

II. FEATURES
1. Materials: Virgin polypropylene
2. Chemically resistant to alcohols and mild organic solvents
3. Transparent wall permits easy viewing of tube contents
4. Temperature range: stable from -20ºC to 100ºC
5. Tested to withstand centrifugation of 6,000 RCF in a fully supported rotor
6. Certified RNase & DNase Free
7. Compatible with most popular 96-well thermal cyclers

III. PCR PLATES DESIGN
1. The plate has a working volume of 0.2ml per well.
2. The half-skirted plate provides superior rigidity and is easy to insert and extract.
3. Ultra-thin walls of uniform thickness - accelerate heat transfer leading to shorter cycle times and more consistent results.
4. Clearly visible with either clear or turbid samples.
5. Alphanumeric well coding available to further assist in sample storage and organization.
6. Available in five colors: clear, pink, green, blue and yellow.

IV. PACKAGING
1.96-well PCR Plates: 25 plates/pack, 4 packs/case.
 
V. DESCRIPTION 
Cat # Well Skirt Color Sterile Unit
60-0056 96-well Half-Skirted Clear NO 25/Pack, 100/Case
60-0156 96-well Half-Skirted Pink NO 25/Pack, 100/Case
60-0256 96-well Half-Skirted Green NO 25/Pack, 100/Case
60-0356 96-well Half-Skirted Blue NO 25/Pack, 100/Case
60-0456 96-well Half-Skirted Yellow NO 25/Pack, 100/Case

 

96-Well 0.2ml PCR Plates, Non-Sterile, Half-Skirted, Dnase & Rnase Free, Clear,96-Well 0.2ml PCR Plates, Non-Sterile, Half-Skirted, Dnase & Rnase Free, Clear,96-Well 0.2ml PCR Plates, Non-Sterile, Half-Skirted, Dnase & Rnase Free, Clear,96-Well 0.2ml PCR Plates, Non-Sterile, Half-Skirted, Dnase & Rnase Free, Clear,
1.What are the main factors that influence the maximum centrifugal acceleration force?

Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP