• Biologix Non-Pyrogenic 0.22/0.45 μ M Pore Size Sterile Syringe Filters
  • Biologix Non-Pyrogenic 0.22/0.45 μ M Pore Size Sterile Syringe Filters
  • Biologix Non-Pyrogenic 0.22/0.45 μ M Pore Size Sterile Syringe Filters
  • Biologix Non-Pyrogenic 0.22/0.45 μ M Pore Size Sterile Syringe Filters
  • Biologix Non-Pyrogenic 0.22/0.45 μ M Pore Size Sterile Syringe Filters
  • Biologix Non-Pyrogenic 0.22/0.45 μ M Pore Size Sterile Syringe Filters

Biologix Non-Pyrogenic 0.22/0.45 μ M Pore Size Sterile Syringe Filters

Disposable: Disposable
Certification: CE, ISO, ISO9001
Reactant State: Liquid
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Order Sample
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Biologix Non-Pyrogenic 0.22/0.45 μ M Pore Size Sterile Syringe Filters pictures & photos
Biologix Non-Pyrogenic 0.22/0.45 μ M Pore Size Sterile Syringe Filters
US $0.1-0.6 / Piece
Min. Order: 100 Pieces
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
08-PES1322R/08-PES2522R/08-PES3022R/08-PES3322S
Material
Rubber / Plastic
Sterile
Gamma Radiation Sterilized
Other
Non-Pyrogenic
Size
0.22/0.45 μm
Sterilized
Gamma Ray Pre-Sterilized
Unit
100 /Pack, 4 Packs/Case, 100 /Pack, 8 Packs/Case
Membrane
Pes
Transport Package
1 /Bag, 100 Bags/Case
Specification
0.22/0.45 μ m
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China
Production Capacity
100000 Cases/Month

Packaging & Delivery

Package Size
7.48cm * 5.71cm * 8.07cm
Package Gross Weight
3.000kg

Product Description

Biologix Non-Pyrogenic 0.22/0.45 μm Pore Size Sterile Syringe Filters

Feature:

· Non-pyrogenic 0.22/0.45 μm Pore Size Sterile Syringe Filters

· We have a wide range of diameters available 13, 25, 30mm: the right size for the right volume or particle load

· High flow rate, high throughput, shorten filtration time

· PES has low protein adsorption and good hydrophilicity

· Equipped with PES membrane: Provides >98.5% protein recovery

· Pre-sterilized: It can be used for sterile filtration and clarification of biological fluids
· Pyrogen-free, low extractables and surfactant-free ensuring filtrate purity

· Excellent throughput, for faster filtration and more process volume
· Gamma radiation sterilized
· Individually packaged to prevent cross contamination

It can be used in:

· Sterile filtration and clarification of biological fluids

· Tissue culture media preparation

· Protein and enzyme filtration

· Hybridization buffers

· Other aqueous solution

Biologix Non-Pyrogenic 0.22/0.45 μ M Pore Size Sterile Syringe Filters
Biologix Non-Pyrogenic 0.22/0.45 μ M Pore Size Sterile Syringe Filters

Ordering Information

Cat # Description Unit
08-PES1322R Membrane: PES, pore size: 0.22μm, diameter:13mm. Female luer lock + male luer slip. Individually packed. 100 Pcs/Pack, 8 Packs/Case, Case of 800
08-PES2522R Membrane: PES, pore size: 0.22μm, diameter:25mm. Female luer lock + male luer slip. Individually packed. 100 Pcs/Pack, 4 Packs/Case, Case of 400
08-PES3022R Membrane: PES, pore size: 0.22μm, diameter:30mm. Female luer lock + male luer slip. Individually packed. 100 Pcs/Pack, 4 Packs/Case, Case of 400
08-PES3322S Membrane: PES, pore size: 0.22μm, diameter:33mm. Double luer lock.  Individually packed. 100 Pcs/Pack, 4 Packs/ Case,  Case of 400
08-PES3345S Membrane: PES, pore size: 0.45μm, diameter:33mm. Double luer lock. Individually packed. 100 Pcs/Pack, 4 Packs/ Case,  Case of 400
08-PES3322M Membrane: PES, pore size: 0.22μm, diameter:33mm. Female luer lock + male luer slip. Individually packed. 100 Pcs/Pack, 4 Packs/ Case,  Case of 400
08-PES3345M Membrane: PES, pore size: 0.45μm, diameter:33mm. Female luer lock + male luer slip. Individually packed. 100 Pcs/Pack, 4 Packs/ Case,  Case of 400
08-CA3022R Membrane: CA, pore size: 0.22μm, diameter:30mm. Female luer lock + male luer slip. Individually packed. 100 Pcs/Pack, 4 Packs/ Case,  Case of 400
08-CA3045R Membrane: CA, pore size: 0.45μm, diameter:30mm. Female luer lock + male luer slip. Individually packed. 100 Pcs/Pack, 4 Packs/ Case, Case of 400

 

Biologix Non-Pyrogenic 0.22/0.45 μ M Pore Size Sterile Syringe Filters

1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2. What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3. What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Biologix Non-Pyrogenic 0.22/0.45 μ M Pore Size Sterile Syringe Filters pictures & photos
Biologix Non-Pyrogenic 0.22/0.45 μ M Pore Size Sterile Syringe Filters
US $0.1-0.6 / Piece
Min. Order: 100 Pieces
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP