• 10UL PP Material Autoclavable Pipette Tips Sterile Tips for Lab Use
  • 10UL PP Material Autoclavable Pipette Tips Sterile Tips for Lab Use
  • 10UL PP Material Autoclavable Pipette Tips Sterile Tips for Lab Use
  • 10UL PP Material Autoclavable Pipette Tips Sterile Tips for Lab Use
  • 10UL PP Material Autoclavable Pipette Tips Sterile Tips for Lab Use
  • 10UL PP Material Autoclavable Pipette Tips Sterile Tips for Lab Use

10UL PP Material Autoclavable Pipette Tips Sterile Tips for Lab Use

Disposable: Disposable
Certification: CE, ISO, FDA
Material: Rubber / Plastic
Certifications: CE ISO FDA
Volume: 10UL 200UL 100UL Pipet Tips
Sterile: Eo Sterile
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
21-0010
Rack
96 Tips or 100 Tips Per Rack
Dnase & Rnase Free
Dnase & Rnase Free
Non-Pyrogen
Non-Pyrogen
Low Retention
Optional
Universal
Universal
Application
Gilson Thermo Biohit Rainin Dlab More
Transport Package
Racked Pack
Specification
10UL 200UL 1000UL
Trademark
Biologix Brand
Origin
Changzhou, Jiangsu
Production Capacity
1000000 Cases/Month

Product Description

10UL PP Material Autoclavable Pipette Tips Sterile Rnase And Dnase Free
 
10UL PP Material Autoclavable Pipette Tips Sterile Tips for Lab Use
10UL PP Material Autoclavable Pipette Tips Sterile Tips for Lab Use

 
Features:

1. Flexible tail vertebrae, compatible with major brands of pipettes

2. Extra-long design minimizes contamination during handling

3. Made of polypropylene, autoclavable

4. Available in 10μl, 200μl and 1000μl sizes, suitable for standard manual and electronic pipettes

5. 10μl and 200μl tips are graduated, 200μl tips have a beveled point design that reduces sample retention

Extended 1000μl tips facilitate pipetting from deep or narrow containers

6. RNase & DNase free, non-pyrogenic

7. Available in racked package (sterile) and bulk package (non-sterile)

8. RNase & DNase free
9. 10ul Tip are natural clear color

 


Order Information 
Cat # Volume Color Sterile Unit
20-0010 10μl Natural NO 1,000 Tips/Pack, 10 Packs/Case
21-0010 10μl Natural YES 96 Tips/Rack, 100 Racks/Case
20-0200 200μl Yellow No 1,000 Tips/Pack, 10 Packs/Case
21-0200 200μl Yellow YES 96 Tips/Rack, 100 Racks/Case
20-1000 1000μl Blue NO 1,000 Tips/Pack, 10 Packs/Case
20-1250 1000μl Extended Natural NO 1,000 Tips/Pack, 10 Packs/Case
21-1000 1000μl Blue YES 100 Tips/Rack, 60 Racks/Case
21-1250 1000μl Extended Natural YES 96 Tips/Pack, 60 Racks/Case
20-1251 1000μl Extra-long Blue NO 1,000 Tips/Bag, 10 Bags/Case
10UL PP Material Autoclavable Pipette Tips Sterile Tips for Lab Use10UL PP Material Autoclavable Pipette Tips Sterile Tips for Lab Use10UL PP Material Autoclavable Pipette Tips Sterile Tips for Lab Use10UL PP Material Autoclavable Pipette Tips Sterile Tips for Lab Use

1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP