• The Most Suitable Filtration Devices for Life Science Applications
  • The Most Suitable Filtration Devices for Life Science Applications
  • The Most Suitable Filtration Devices for Life Science Applications
  • The Most Suitable Filtration Devices for Life Science Applications

The Most Suitable Filtration Devices for Life Science Applications

Disposable: Disposable
Certification: CE, ISO
Reactant State: Liquid
Material: Rubber / Plastic
Character: Tissue Culture Media Preparation
Transport Package: 400packs/Case
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
08-PES1322R/08-PES2522R
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China
HS Code
8421299090
Production Capacity
200 Cases/Week

Product Description

The Most Suitable Filtration Devices for Life Science Applications
The Most Suitable Filtration Devices for Life Science Applications

Characteristic
 

Features:

* Single Use and Gamma Ray pre-sterilized.  

* Sterile graded 0.2um membrane: LRV>7 for Brevundimonas diminuta, ATCC19146.  

* Non-pyrogenic, low extractables and surfactant-free ensures purity of filtrate.  

* Extreme-low Protein Binding <1.5% (PES).   

* Excellent Thoughput, for faster filtration and more process volume.

Applications:

1. Sterile filtration and clarification of biological fluids.

2. Tissue culture media preparation.

3. Protein and enzyme filtration.

4. Hybridization buffers.

5. Other aqueous solution.

    Ordering Information
     
    CAT#   DECRIPTION  TO REPLACE Pack Size
    08-PES1322R

    Membrane: PES, pore size: 0.22μm, diameter:13mm. 

    Female luer lock + male luer slip. Extreme-low protein 

    binding. Individually packed.

    Millipore SLGV013SL

    Whatman 6780-1302/6791-1302

    Pall 4602

    100 Pcs/Pack, 8 Packs/Case, 

    Case of 800

    08-PES2522R

    Membrane: PES, pore size: 0.22μm, diameter:25mm. 

    Female luer lock + male luer slip. Extreme-low protein 

    binding. Individually packed.

    Millipore SLMP025SS/SLMP025SS

    Whatman 6780-2502/6780-2512/

    9913-2502

    Pall 4612/4902/4907/4520

    100 Pcs/Pack, 4 Packs/Case, 

    Case of 400

    08-PES3022R

    Membrane: PES, pore size: 0.22μm, diameter:30mm. 

    Female luer lock + male luer slip. Extreme-low protein 

    binding. Individually packed.

    Millipore SLMP025SS/SLMP025SS

    Whatman 6780-2502/6780-2512

    Pall 4612/4902

    100 Pcs/Pack, 4 Packs/Case, 

    Case of 400

    08-PES3322S

    Membrane: PES, pore size: 0.22μm, diameter:33mm. 

    Double luer lock. Extreme-low protein binding.  Individually packed.

    Sartorius16532----GUK

    Sartorius16532------K

    Sartorius16532----------Q

    Sartorius 16534---------K

    100 Pcs/Pack, 4 Packs/Case, 

    Case of 400

    08-PES3345S

    Membrane: PES, pore size: 0.45μm, diameter:33mm. 

    Double luer lock. Extreme-low protein binding. Individually packed.

    Sartorius16537-----K 

    Sartorius16537-----Q

    Sartorius 16555----K

    100 Pcs/Pack, 4 Packs/Case, 

    Case of 400

    08-PES3322M

    Membrane: PES, pore size: 0.22μm, diameter:33mm. 

    Female luer lock + male luer slip. High pressure resistance. 

    Individually packed.

    Millipore SLGP033RB/SLGP033RK/ SLGP033

    RS/SLGV033RS/ SLGV033RB/SLGV033RK

    Sartorius 16541----K/16541----Q

    Pall 4652

    Whatman1046-2200/1046-2205

    100 Pcs/Pack, 4 Packs/Case, 

    Case of 400

    08-PES3345M

    Membrane: PES, pore size: 0.45μm, diameter:33mm. 

    Female luer lock + male luer slip. High pressure resistance. 

    Individually packed.

    Millipore SLHP033RB/SLHP033RS/ SLHV033

    RS/ SLHV033RB/ SLHV033RK

    Sartorius16533----K/16533----Q

    Pall 4654/4406

    Whatman 1046-2100

    100 Pcs/Pack, 4 Packs/Case, 

    Case of 400

    08-CA3022R

    Membrane: CA, pore size: 0.22μm, diameter:30mm. 

    Female luer lock + male luer slip. High biocompatibility. 

    Individually packed.

    Sartorius 17597----K

    Whatman 1046-2200

    Whatman 1046-2205

    100 Pcs/Pack, 4 Packs/Case, 

    Case of 400

    08-CA3045R

    Membrane: CA, pore size: 0.45μm, diameter:30mm. 

    Female luer lock + male luer slip. High biocompatibility. 

    Individually packed.

    Whatman 1046-2100

    100 Pcs/Pack, 4 Packs/Case, 

    Case of 400

    09-PES2250

    Vacuum filtration unit, membrane: PES, pore size: 0.22μm, 

    diameter:90mm, funnel volume: 500ml, receiver volume: 500ml. 

    Thermo 566-0020

    Corning 431097

    Millipore S2GPU05RE 

    Millipore S2GVU05RE 

    Sartorius 180C2----------E

    12
    09-PES2250F

    Vacuum filtration unit-funnel, membrane: PES, pore size: 0.22μm,

    diameter:90mm, funnel volume: 500ml.   

    Millipore SCGPT05RE/ S2GPT10RE /SCGPT10RE 

    Sartorius 180C5----------E/

    180C6----------E

    Thermo 595-4520/ 597-4520

    Corning 431118/ 431174

    24
    09-CA2250

    Vacuum filtration unit-funnel, membrane: CA, pore size: 0.22μm, 

    diameter:90mm, funnel volume: 500ml, receiver volume: 500ml.   

    Thermo 156-4020/156-0020

    Corning 430769

    12
    09-CA2250F

    Vacuum filtration unit-funnel, membrane: CA, pore size: 0.22μm, 

    diameter:90mm, funnel volume: 500ml.

    Thermo 291-4520/292-4520

    Corning 430513/430514/430515

    24

     

    The Most Suitable Filtration Devices for Life Science Applications

    1.What are the main factors that influence the maximum centrifugal acceleration force?
    Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
    The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
    Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

    2.What are autoclaving guidelines of plastics?

    To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

    3.What are Biologix's Commitments to Quality?
    We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now

    You Might Also Like

    Gold Member Since 2021

    Suppliers with verified business licenses

    Manufacturer/Factory
    Type of Ownership
    Limited Company
    Management System Certification
    ISO 9001, GMP