• Cell Scraper PE Gamma Radiation Sterile 18cm 25cm
  • Cell Scraper PE Gamma Radiation Sterile 18cm 25cm
  • Cell Scraper PE Gamma Radiation Sterile 18cm 25cm
  • Cell Scraper PE Gamma Radiation Sterile 18cm 25cm
  • Cell Scraper PE Gamma Radiation Sterile 18cm 25cm
  • Cell Scraper PE Gamma Radiation Sterile 18cm 25cm

Cell Scraper PE Gamma Radiation Sterile 18cm 25cm

Disposable: Disposable
Certification: CE, ISO, FDA
Material: PE
Handle Length: 18cm
Sterile: Gamma Radiation Sterilized
Package: Individual
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
18cm 25cm
Unit
1 /Bag, 100 Bags/Case
Non-Pyrogenic
Yes
Transport Package
1/Bag, 100bags/Case
Specification
1/bag, 100bags/case
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China
HS Code
3926909090
Production Capacity
200 Cases/Week

Product Description

18cm Sterile Individual Cell Lifters
 
Cell Scraper PE Gamma Radiation Sterile 18cm 25cm
Features:
  1. Made of polyethylene
  2. One-piece design and chiseled blade provide improved control while minimizing damage to cells
  3. Gamma radiation sterilized, non-pyrogenic
 
 
 70-1180  Cell Scrapers, Sterile, Handle Length 18cm, Blade Length 1.8cm, 100 Pieces/Case
 70-1250  Cell Scrapers, Sterile, Handle Length 25cm, Blade Length 1.8cm, 200 Pieces/Case
 70-2180  Cell Lifters, Sterile, Handle Length 18cm, Blade Length 2.0cm, 100 Pieces/Case
Cell Scraper PE Gamma Radiation Sterile 18cm 25cm1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2.  What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3.  What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP