• Spheroid Dish for Culturing and Counting The Spheroid
  • Spheroid Dish for Culturing and Counting The Spheroid

Spheroid Dish for Culturing and Counting The Spheroid

After-sales Service: 3 Years
Warranty: 3 Years
Customized: Non-Customized
Structure: Portable
Material: PS Material
Certification: CE, ISO, ISO9001
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
110350, 111350
Application
Lab
Type
Culture Supplies
Color
Clear
Volume
0.2ml
Sterile
Yes
Transport Package
3/15
Specification
35.00 mm x 10.00 mm
Trademark
BIOLOGIX
Origin
America
Production Capacity
200 Cases/Week

Product Description

Features

 Mesh thickness: 137
 Mesh pore size: 200
 Non-treated: better for counting spheroids (Cat. No. 110350)
 Low Binding treated: better for spheroid culturing (Cat. No. 111350)
 Non-pyrogenic
 Non-cytotoxic
 DNase / RNase - free
 Human DNA - free
 
Cat# Material (Dish / Mesh) Dish Style (mm) Internal Well Dimension     d x h (mm) Working Vol. (ml) Low Binding Treatment Sterile Packaging
110350 PS / PE 35.00 x 10.00 13.00 x 1.00 0.2 No Yes 3/ 15
111350 PS / PE 35.00 x 10.00 25.00 x 1.00 0.8 Yes Yes 3/ 15
Spheroid Dish for Culturing and Counting The SpheroidSpheroid Dish for Culturing and Counting The SpheroidSpheroid Dish for Culturing and Counting The Spheroid
  1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2. What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3. What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers' lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP