• 0.5ml 1.5ml and 2.0ml PP Disposable Laboraotry Microcentrifuge Plastic Tubes
  • 0.5ml 1.5ml and 2.0ml PP Disposable Laboraotry Microcentrifuge Plastic Tubes
  • 0.5ml 1.5ml and 2.0ml PP Disposable Laboraotry Microcentrifuge Plastic Tubes
  • 0.5ml 1.5ml and 2.0ml PP Disposable Laboraotry Microcentrifuge Plastic Tubes
  • 0.5ml 1.5ml and 2.0ml PP Disposable Laboraotry Microcentrifuge Plastic Tubes
  • 0.5ml 1.5ml and 2.0ml PP Disposable Laboraotry Microcentrifuge Plastic Tubes

0.5ml 1.5ml and 2.0ml PP Disposable Laboraotry Microcentrifuge Plastic Tubes

Certification: CE, ISO, FDA
Material: PP
Capacity: 0.5ml 1.5ml 2.0ml
Sterilization: Pre-Sterile with Radiation
Pyrogenic: Certified Free of Pyrogen, Nucleases, Foreign DNA
Working Temperature: -20 C to 121c
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
80-0500 80-0015 80-1500 80-1501 80-1502 80-1503 8
Color
Clear
Sterile
No
Rcf
20, 000
Transport Package
500 Pieces/Pack, 10 Packs/Case
Trademark
Biologix Brand
Origin
Changzhou, Jiangsu
HS Code
3917220000
Production Capacity
500cases/Month

Product Description

0.5ml 1.5ml And 2.0ml PP Disposable Laboraotry Microcentrifuge Plastic Tubes RNase DNase free
0.5ml 1.5ml and 2.0ml PP Disposable Laboraotry Microcentrifuge Plastic Tubes0.5ml 1.5ml and 2.0ml PP Disposable Laboraotry Microcentrifuge Plastic Tubes0.5ml 1.5ml and 2.0ml PP Disposable Laboraotry Microcentrifuge Plastic Tubes
Characteristic
 

1.Made of high quality medical grade polypropylene

2.Transparent tube walls permit easy viewing of contents

  Beveled lip for convenient one-handed operation

  Writing area and attached flat cap for labeling

3.80-0500, 80-1500, 80-1500, 80-1501, 80-1502, 80-1503: RNase & DNase free

 

Specifications
 

1.Working temperature: stable from -20°C to 121°C

2.Can withstand high speed centrifugation of 20,000 RCF

Ordering Information
 

Cat # Volume Color Sterile Unit
80-0500

0.5ml

Clear No 500 Pieces/Pack, 10 Packs/Case
80-0015 1.5ml Clear No 500 Pieces/Pack, 10 Packs/Case
80-1500 1.5ml Clear No 500 Pieces/Pack, 10 Packs/Case
80-0020 2.0ml Clear No 500 Pieces/Pack, 10 Packs/Case
80-1501* 1.5ml Red No 500 Pieces/Pack, 10 Packs/Case
80-1502* 1.5ml Yellow No 500 Pieces/Pack, 10 Packs/Case
80-1503* 1.5ml Blue No 500 Pieces/Pack, 10 Packs/Case

* Call for details


0.5ml 1.5ml and 2.0ml PP Disposable Laboraotry Microcentrifuge Plastic Tubes0.5ml 1.5ml and 2.0ml PP Disposable Laboraotry Microcentrifuge Plastic Tubes0.5ml 1.5ml and 2.0ml PP Disposable Laboraotry Microcentrifuge Plastic Tubes0.5ml 1.5ml and 2.0ml PP Disposable Laboraotry Microcentrifuge Plastic Tubes

1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP