Laboratory Consumsble Plastic 25/ 75/175 Cm² Filter/Plug Cap Tc Treated Cell Culture Flasks

Product Details
Disposable: Disposable
Certification: CE, ISO
Material: PS Material
Still deciding? Get samples of US$ 0/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Laboratory Consumsble Plastic 25/ 75/175 Cm² Filter/Plug Cap Tc Treated Cell Culture Flasks
  • Laboratory Consumsble Plastic 25/ 75/175 Cm² Filter/Plug Cap Tc Treated Cell Culture Flasks
  • Laboratory Consumsble Plastic 25/ 75/175 Cm² Filter/Plug Cap Tc Treated Cell Culture Flasks
  • Laboratory Consumsble Plastic 25/ 75/175 Cm² Filter/Plug Cap Tc Treated Cell Culture Flasks
  • Laboratory Consumsble Plastic 25/ 75/175 Cm² Filter/Plug Cap Tc Treated Cell Culture Flasks
  • Laboratory Consumsble Plastic 25/ 75/175 Cm² Filter/Plug Cap Tc Treated Cell Culture Flasks
Find Similar Products

Basic Info.

Model NO.
07-8025 07-8075 07-8175 07-9025 07-9075 07-9175
Color
Blue
Sterilized
Gamma Radiation
Cap Type
Filter or Plug
Size
25/75/175 Cm²
Working Volume
7/25/50ml
Surface Treatment
Tc Treated
Sterile
Yes
Transport Package
40 Packs/Case
Specification
07-8025 07-8075 07-8175 07-9025 07-9075 07-9175
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China
HS Code
3923300000
Production Capacity
200 Cases/Week

Packaging & Delivery

Package Size
18.00cm * 15.00cm * 11.00cm
Package Gross Weight
3.500kg

Product Description

Laboratory Consumsble Plastic 25/ 75/175 cm² Filter/Plug Cap TC Treated Cell Culture Flasks

Feature:
· 25 cm², 75 cm², 175 cm² Treated Tissue Cell Culture Flask
· Plug cap and filter cap options available for all flask sizes
· Plug caps completely isolate the culture from the outside environment
· Filter caps prevent cross-contamination while meeting the requirements for gas exchange
· Short, wide, angled neck design for easy access
· Gamma radiation sterilized
· Non-pyrogenic, non-cytotoxic
· DNase & RNase free, human DNA free
· TC treated

Laboratory Consumsble Plastic 25/ 75/175 Cm² Filter/Plug Cap Tc Treated Cell Culture Flasks
Laboratory Consumsble Plastic 25/ 75/175 Cm² Filter/Plug Cap Tc Treated Cell Culture Flasks
Ordering Information
Cat # Material Cap Type Culture Area(cm2) Working Volume(ml) Surface Treatment Sterilized Unit
07-8025 PS Filter 25 7 Ye Gamma radiation sterilized 5/Bag, 40 Bags/Case
07-8075 PS Filter 75 25 Yes Gamma radiation sterilized 5/Bag, 20 Bags/Case
07-8175 PS Filter 175 50 Yes Gamma radiation sterilized 5/Bag, 8 Bags/Case
07-9025 PS Plug 25 7 Yes Gamma radiation sterilized 5/Bag, 40 Bags/Case
07-9075 PS Plug 75 25 Yes Gamma radiation sterilized 5/Bag, 20 Bags/Case
07-9175 PS Plug 175 50 Yes Gamma radiation sterilized 5/Bag, 8 Bags/Case

 

Laboratory Consumsble Plastic 25/ 75/175 Cm² Filter/Plug Cap Tc Treated Cell Culture Flasks1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2.What are autoclaving guidelines of plastics?

To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 