10/20/100/200/300/1000UL Pipet Tips Disposable

Product Details
After-sales Service: 5 Years
Warranty: 5 Years
Disposable: Disposable
Still deciding? Get samples of US$ 0/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • 10/20/100/200/300/1000UL Pipet Tips Disposable
  • 10/20/100/200/300/1000UL Pipet Tips Disposable
  • 10/20/100/200/300/1000UL Pipet Tips Disposable
  • 10/20/100/200/300/1000UL Pipet Tips Disposable
  • 10/20/100/200/300/1000UL Pipet Tips Disposable
  • 10/20/100/200/300/1000UL Pipet Tips Disposable
Find Similar Products

Basic Info.

Model NO.
10/20/50/100/200/1000 ul
Certification
CE, ISO, FDA
Material
Rubber / Plastic
Characteristic
Rnase & Dnase Free
Available
Racked Package and Bulk Package
Features
Flexible Tail Vertebrae
Autoclavable
Yes
Rnase&Dnase Free
Yes
Certificate
Yes
Transport Package
9600racks/Case
Specification
10 200 1000
Trademark
BIOLOGIX
Origin
Changzhou, Jiangsu, China.

Packaging & Delivery

Package Size
5.00cm * 3.00cm * 1.00cm
Package Gross Weight
1.000kg

Product Description

10 ul 200 ul 1000 ul Pipette Tips Sterile RNase & DNase free
10/20/100/200/300/1000UL Pipet Tips Disposable
10/20/100/200/300/1000UL Pipet Tips Disposable
 
Characteristic
 

Flexible tail vertebrae, compatible with major brands of pipettes

Extra-long design minimizes contamination during handling

Made of polypropylene, autoclavable

Available in 10μl, 200μl and 1000μl sizes, suitable for standard manual and electronic pipettes

10μl and 200μl tips are graduated, 200μl tips have a beveled point design that reduces sample retention

Extended 1000μl tips facilitate pipetting from deep or narrow containers

RNase & DNase free, non-pyrogenic

Available in racked package (sterile) and bulk package (non-sterile)

RNase & DNase free

 10ul Tip are natural clear color


Ordering Information

     
    Cat # Volume Color Sterile Unit
    20-0010 10μl Natural NO 1,000 Tips/Pack, 10 Packs/Case
    21-0010 10μl Natural YES 96 Tips/Rack, 100 Racks/Case
    20-0200 200μl Yellow No 1,000 Tips/Pack, 10 Packs/Case
    21-0200 200μl Yellow YES 96 Tips/Rack, 100 Racks/Case
    20-1000 1000μl Blue NO 1,000 Tips/Pack, 10 Packs/Case
    20-1250 1000μl Extended Natural NO 1,000 Tips/Pack, 10 Packs/Case
    21-1000 1000μl Blue YES 100 Tips/Rack, 60 Racks/Case
    21-1250 1000μl Extended Natural YES 96 Tips/Pack, 60 Racks/Case
    20-1251 1000μl Extra-long Blue NO 1,000 Tips/Bag, 10 Bags/Case
    10/20/100/200/300/1000UL Pipet Tips Disposable10/20/100/200/300/1000UL Pipet Tips Disposable10/20/100/200/300/1000UL Pipet Tips Disposable10/20/100/200/300/1000UL Pipet Tips Disposable
    1. What are the main factors that influence the maximum centrifugal acceleration force?

    Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
    The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
    Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

    2. What are autoclaving guidelines of plastics?
    To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

    3. What are Biologix's Commitments to Quality?
    We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 


     

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now
    Contact Supplier