Laboratory Consumable Plastic PS 35/60/90/150mm Diameter Steriled TC Treated Cell Culture Dishes

Product Details
Color: Clear
Type: Culture Dish
Size: 35X10/60X15/90X20/150X25mm
Still deciding? Get samples of US$ 0/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Laboratory Consumable Plastic PS 35/60/90/150mm Diameter Steriled TC Treated Cell Culture Dishes
  • Laboratory Consumable Plastic PS 35/60/90/150mm Diameter Steriled TC Treated Cell Culture Dishes
  • Laboratory Consumable Plastic PS 35/60/90/150mm Diameter Steriled TC Treated Cell Culture Dishes
  • Laboratory Consumable Plastic PS 35/60/90/150mm Diameter Steriled TC Treated Cell Culture Dishes
  • Laboratory Consumable Plastic PS 35/60/90/150mm Diameter Steriled TC Treated Cell Culture Dishes
  • Laboratory Consumable Plastic PS 35/60/90/150mm Diameter Steriled TC Treated Cell Culture Dishes
Find Similar Products

Basic Info.

Model NO.
66-1560/66-1501/66-1701/66-1515
Sterile
Yes
Tc Treated
Yes
External Grip
Yes
Transport Package
200/500/Case
Trademark
BIOLOGIX
Origin
Changzhou, Jiangsu
HS Code
3926909090
Production Capacity
500 Cases/Month

Packaging & Delivery

Package Size
10.00cm * 8.00cm * 5.00cm
Package Gross Weight
2.600kg

Product Description

Laboratory Consumable Plastic PS 335/60/90/150mm Diameter Steriled TC Treated Cell Culture Dishes

Feature:

· Made of high quality medical grade polystyrene

· Lid design promotes effective gas exchange

· External grip for easier handling (07-3035 and 07-3060)

· Raised edges for convenient stacking

· Vacuum plasma surface treatment ensures excellent cell adhesion

· Smooth, transparent materials facilitate observation of cells through a microscope

· Electron beam sterilized

· Non-pyrogenic, non-cytotoxic

· DNase & RNase free, human DNA free

· TC treated


Laboratory Consumable Plastic PS 35/60/90/150mm Diameter Steriled TC Treated Cell Culture Dishes
Laboratory Consumable Plastic PS 35/60/90/150mm Diameter Steriled TC Treated Cell Culture Dishes
Product Details
Laboratory Consumable Plastic PS 35/60/90/150mm Diameter Steriled TC Treated Cell Culture Dishes
Ordering Information
Cat # Dish Style (DxH)(mm) Internal Dimensions (DxH)(mm)

Culture

Area(cm2)

Working Volume(ml) External Grip TC Treated Sterile Unit
07-3035 35x10 34.3x9.3 9.4 3 Yes Yes Yes 10/Bag, 50 Bags/Case
07-3060 60x15 52.8x12.8 21.5 5 Yes Yes Yes 10/Bag, 50 Bags/Case
07-3100 90x20 86.26x17.7 57.5 12.5 No Yes Yes 10/Bag, 20 Bags/Case
07-3150 150x25 140.2×23.3 148 35 No Yes Yes 10/Bag, 12 Bags/Case

Laboratory Consumable Plastic PS 35/60/90/150mm Diameter Steriled TC Treated Cell Culture Dishes1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier