Laboratory Consumable 25ml/50ml/55/100ml Plastic PS/PP/PVC Individually Wrapped Solution Basins

Product Details
Disposable: Disposable
Certification: CE, ISO, FDA
Reactant State: Solid
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Laboratory Consumable 25ml/50ml/55/100ml Plastic PS/PP/PVC Individually Wrapped Solution Basins
  • Laboratory Consumable 25ml/50ml/55/100ml Plastic PS/PP/PVC Individually Wrapped Solution Basins
  • Laboratory Consumable 25ml/50ml/55/100ml Plastic PS/PP/PVC Individually Wrapped Solution Basins
  • Laboratory Consumable 25ml/50ml/55/100ml Plastic PS/PP/PVC Individually Wrapped Solution Basins
  • Laboratory Consumable 25ml/50ml/55/100ml Plastic PS/PP/PVC Individually Wrapped Solution Basins
  • Laboratory Consumable 25ml/50ml/55/100ml Plastic PS/PP/PVC Individually Wrapped Solution Basins
Find Similar Products

Basic Info.

Model NO.
25-1025/25-1202/25-0052/25-0051/25-1100
Material
Rubber / Plastic
Volume
25/50/55/100ml
Color
Assorted Colors
Sterile
Sterile/Non-Sterile Are Available
Package
Individually Wrapped
Unit
1 /Bag, 100 Bags/Case
Total
50/100/800/Case
Transport Package
100 /Case
Specification
1 /Bag, 100 Bags/Case
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China

Packaging & Delivery

Package Size
18.00cm * 20.00cm * 11.00cm
Package Gross Weight
10.000kg
Lead Time
2 days (1 - 5000 Pieces)
To be negotiated ( > 5000 Pieces)

Product Description

Laboratory Consumable 25ml/50ml/55/100ml Plastic PS/PP/PVC Individually Wrapped Solution Basins

Feature:
· Laboratory Consumable Solution Basins
· Three materials: PVC, PS, PP
· Sterile and non-sterile basins are available
· PVC basin walls are highly transparent, making it easy to observe samples during experiments
· PP basins are stable and easy to use
· S single-channel basins are available in three sizes: 25ml, 55ml and 100ml
· V-bottom design basins are available in two sizes: 25ml and 55ml

Laboratory Consumable 25ml/50ml/55/100ml Plastic PS/PP/PVC Individually Wrapped Solution Basins
Laboratory Consumable 25ml/50ml/55/100ml Plastic PS/PP/PVC Individually Wrapped Solution Basins
Ordering Information
Cat # Volume Material Color Sterile Autoclavable Individual Package Unit Total
25-1025 25 PS White Yes No Yes 1 Basin/Bag, 100 Bags/Case 100 Pieces/Case
25-1202 50 PP Assorted Colors No Yes No 25 Basins/Bag, 4 Bags/Case 100 Pieces/Case
25-0052 55 PVC Clear No No No 100 Basins/Bag, 8 Bags/Case 800 Pieces/Case
25-0051 55 PS White Yes No Yes 1 Basin/Bag, 100 Bags/Case 100 Pieces/Case
25-1100 100 PS White Yes No Yes 1 Basin/Bag, 50 Bags/Case 50 Pieces/Case

 

Laboratory Consumable 25ml/50ml/55/100ml Plastic PS/PP/PVC Individually Wrapped Solution Basins
1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
 
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier