15ml Centrifuge Tubes Racked, Flat Cap, Sterile

Product Details
Material: PP
Hardness: Hard Tube
Type: PP Material
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • 15ml Centrifuge Tubes Racked, Flat Cap, Sterile
  • 15ml Centrifuge Tubes Racked, Flat Cap, Sterile
  • 15ml Centrifuge Tubes Racked, Flat Cap, Sterile
  • 15ml Centrifuge Tubes Racked, Flat Cap, Sterile
  • 15ml Centrifuge Tubes Racked, Flat Cap, Sterile
  • 15ml Centrifuge Tubes Racked, Flat Cap, Sterile
Find Similar Products

Basic Info.

Color
Clear
Working Temperature
From -20 Degree to 121 Degree
Sterile
Gamma Radiation
Transport Package
500/Case
Specification
CE, ISO, FDA
Trademark
Biologix
Origin
Changzhou, Jiangsu, China
HS Code
39172200
Production Capacity
200cases/Month

Product Description

15ml Centrifuge Tubes Racked, Flat Cap, Sterile
15ml Centrifuge Tubes Racked, Flat Cap, Sterile
15ml Centrifuge Tubes Racked, Flat Cap, Sterile
Characteristic
 

Tubes: made of strong, highly transparent medical grade polypropylene

Flat-top caps: made of medical grade polyethylene

Plug-seal screw on caps: made of medical grade polypropylene

15ml and 50ml conical tubes available; large white writing area for easy marking

Double threaded design reduces cross-threading; caps are easily opened and closed

Flat-top caps can be written on

Gamma radiation sterilized, non-pyrogenic

Available in racked package (sterile) or bulk package (sterile & non-sterile)

RNase & DNase free

 

Specifications

Working temperature: stable from -20°C to 121°C (except flat-top cap)

15ml and 50ml tubes can withstand centrifugation of 8,400 and 9,400 RCF

respectively

Sealing test: complies with The International Air Transport Association (IATA)

Safety Standards

 

Ordering Information

    Cat # Volume Caps Sterile Package Unit
    10-9151

    15ml

    Flat Top Yes Rack 50 Sets/Rack, 10 Racks/Case
    10-9152 15ml Flat Top Yes Bulk 25 Sets/Pack, 20 Packs/Case
    CTW00150 15ml Flat Top Yes Bulk 50 Sets/Pack, 10 Packs/Case
    10-9501 50ml Flat Top Yes Rack 25 Sets/Rack, 20 Racks/Case
    10-9502 50ml Flat Top Yes Bulk 25 Sets/Pack, 20 Packs/Case
    10-9502E 50ml Flat Top Yes Bulk 25 Sets/Pack, 20 Packs/Case
    10-9815 15ml Flat Top No Bulk 500 Sets/Case
    10-9850 50ml Flat Top No Bulk 500 Sets/Case
    10-0151 15ml Plug Seal Yes Rack 50 Sets/Rack, 10 Racks/Case
    10-0152 15ml Plug Seal Yes Bulk 25 Sets/Pack, 20 Packs/Case
    10-0501 50ml Plug Seal Yes Rack 25 Sets/Pack, 20 Packs/Case
    10-0502 50ml Plug Seal Yes Bulk 25 Sets/Pack, 20 Packs/Case
    10-0815 15ml Plug Seal No Bulk 500 Sets/Case
    10-0850 50ml Plug Seal No Bulk 500 Sets/Case
    15ml Centrifuge Tubes Racked, Flat Cap, Sterile
    15ml Centrifuge Tubes Racked, Flat Cap, Sterile
    15ml Centrifuge Tubes Racked, Flat Cap, Sterile15ml Centrifuge Tubes Racked, Flat Cap, Sterile
    1.What are the main factors that influence the maximum centrifugal acceleration force?
    Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
    The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
    Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

    2.What are autoclaving guidelines of plastics?
    To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

    3.What are Biologix's Commitments to Quality?
    We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 


     

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now
    Contact Supplier