• 0.5ml 1.5ml 2.0ml External Thread Screw Cap Conical Microtubes
  • 0.5ml 1.5ml 2.0ml External Thread Screw Cap Conical Microtubes
  • 0.5ml 1.5ml 2.0ml External Thread Screw Cap Conical Microtubes
  • 0.5ml 1.5ml 2.0ml External Thread Screw Cap Conical Microtubes
  • 0.5ml 1.5ml 2.0ml External Thread Screw Cap Conical Microtubes
  • 0.5ml 1.5ml 2.0ml External Thread Screw Cap Conical Microtubes

0.5ml 1.5ml 2.0ml External Thread Screw Cap Conical Microtubes

Certification: CE, ISO, FDA
Material: Polypropylene
Volume: 0.5/1.5/2.0ml
Color: Clear Brown Pink Green Yellow
Sterile: No
Bottom: Conicalt/Self-Standing
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
81-005x//81-0153/81-0154/81-0203/81-0204/81-0204
Transport Package
5000/Case
Specification
500 Tubes/Pack, 10 Packs/Case
Trademark
Biologix
Origin
China
HS Code
3917220000

Product Description

0.5ml 1.5ml 2.0ml external thread Screw Cap Conical Microtubes
0.5ml 1.5ml 2.0ml External Thread Screw Cap Conical Microtubes0.5ml 1.5ml 2.0ml External Thread Screw Cap Conical Microtubes0.5ml 1.5ml 2.0ml External Thread Screw Cap Conical Microtubes0.5ml 1.5ml 2.0ml External Thread Screw Cap Conical Microtubes0.5ml 1.5ml 2.0ml External Thread Screw Cap Conical Microtubes0.5ml 1.5ml 2.0ml External Thread Screw Cap Conical Microtubes0.5ml 1.5ml 2.0ml External Thread Screw Cap Conical Microtubes
Characteristic:

-- Made of medical grade polypropylene

-- Can be repeatedly frozen and thawed

-- Universal screw threads for use

-- Tubes fit most common rotors

-- Tubes fit standard 1-inch and 2-inch freezer boxes

-- Autoclavable to 121°C and freezable to -86°C

-- 81-0055 0.5ml self-standing vials are brown, and can fit 81-0006 brown caps

--CE/FDA/ISO Certificates are all available from Biologix!

0.5ml 1.5ml 2.0ml External Thread Screw Cap Conical Microtubes
Cat# Type Volume Bottom Sterile Unit
81-0053 Tubes 0.5ml Conical No 500 Tubes/Pack,10 Packs/Case
81-0054 Tubes 0.5ml Self-Standing No 500 Tubes/Pack,10 Packs/Case
81-0055 Tubes 0.5ml Self-Standing No 500 Tubes/Pack,10 Packs/Case
81-0056 Tubes 0.5ml Self-Standing No

100 Tubes/Bag, 5 Bags/Pack,

10 Packs/Case

81-0153 Tubes 1.5ml Conical No 500 Tubes/Pack,10 Packs/Case
81-0154 Tubes 1.5ml Self-Standing No 500 Tubes/Pack,10 Packs/Case
81-0203 Tubes 2.0ml Conical No 500 Tubes/Pack,10 Packs/Case
81-0204 Tubes 2.0ml Self-Standing No 500 Tubes/Pack,10 Packs/Case
81-0204S Tubes 2.0ml Self-Standing Yes 500 Tubes/Pack,10 Packs/Case
81-0205 Tubes 2.0ml Self-Standing No 500 Tubes/Pack,10 Packs/Case
81-0000 Caps - - No 500 /Pack,10 Packs/Case
81-0000S Caps - - Yes 500 /Pack,10 Packs/Case
81-0001* Caps - - No 500 /Pack,10 Packs/Case
81-0002* Caps - - No 500 /Pack,10 Packs/Case
81-0003* Caps - - No 500 /Pack,10 Packs/Case
81-0004* Caps - - No 500 /Pack,10 Packs/Case
81-0005* Caps - - No 500 /Pack,10 Packs/Case
81-0006 Caps - - No 500 /Pack,10 Packs/Case

* Call for details.

 0.5ml 1.5ml 2.0ml External Thread Screw Cap Conical Microtubes

1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP