15ml 50ml Flat Top Centrifuge Tubes Gamma Steriled and Non-Sterile Racked and Bulk Package

Product Details
Certification: CE, ISO
Material: PP Material
Capacity: 15mL
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • 15ml 50ml Flat Top Centrifuge Tubes Gamma Steriled and Non-Sterile Racked and Bulk Package
  • 15ml 50ml Flat Top Centrifuge Tubes Gamma Steriled and Non-Sterile Racked and Bulk Package
  • 15ml 50ml Flat Top Centrifuge Tubes Gamma Steriled and Non-Sterile Racked and Bulk Package
  • 15ml 50ml Flat Top Centrifuge Tubes Gamma Steriled and Non-Sterile Racked and Bulk Package
  • 15ml 50ml Flat Top Centrifuge Tubes Gamma Steriled and Non-Sterile Racked and Bulk Package
  • 15ml 50ml Flat Top Centrifuge Tubes Gamma Steriled and Non-Sterile Racked and Bulk Package
Find Similar Products

Basic Info.

Model NO.
10-9815/9850
Cap
Flat Top
Volume
15ml and 50ml
Type
Centrifuge Tubes
Transport Package
500/Case
Specification
Available in 15ml and 50ml volumes
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China
HS Code
3917220000
Production Capacity
200 Cases/Week

Product Description

15ml 50ml Flat Top Centrifuge Tubes Gamma Steriled and Non-Sterile Racked and Bulk Package15ml 50ml Flat Top Centrifuge Tubes Gamma Steriled and Non-Sterile Racked and Bulk Package
Characteristic
 

1.Tubes: made of strong, highly transparent medical grade polypropylene

2.Flat-top caps: made of medical grade polyethylene

3.Plug-seal screw on caps: made of medical grade polypropylene

4.15ml and 50ml conical tubes available; large white writing area for easy marking

5.Double threaded design reduces cross-threading; caps are easily opened and closed

6.Flat-top caps can be written on

7.Gamma radiation sterilized, non-pyrogenic

8.Available in racked package (sterile) or bulk package (sterile & non-sterile)

9.RNase & DNase free

 

Specifications

Working temperature: stable from -20°C to 121°C (except flat-top cap)

15ml and 50ml tubes can withstand centrifugation of 8,400 and 9,400 RCF

respectively

Sealing test: complies with The International Air Transport Association (IATA)

Safety Standards

    Ordering Information
     
    Cat # Volume Caps Sterile Package Unit
    10-9151

    15ml

    Flat Top Yes Rack 50 Sets/Rack, 10 Racks/Case
    10-9152 15ml Flat Top Yes Bulk 25 Sets/Pack, 20 Packs/Case
    CTW00150 15ml Flat Top Yes Bulk 50 Sets/Pack, 10 Packs/Case
    10-9501 50ml Flat Top Yes Rack 25 Sets/Rack, 20 Racks/Case
    10-9502 50ml Flat Top Yes Bulk 25 Sets/Pack, 20 Packs/Case
    10-9502E 50ml Flat Top Yes Bulk 25 Sets/Pack, 20 Packs/Case
    10-9815 15ml Flat Top No Bulk 500 Sets/Case
    10-9850 50ml Flat Top No Bulk 500 Sets/Case
    10-0151 15ml Plug Seal Yes Rack 50 Sets/Rack, 10 Racks/Case
    10-0152 15ml Plug Seal Yes Bulk 25 Sets/Pack, 20 Packs/Case
    10-0501 50ml Plug Seal Yes Rack 25 Sets/Pack, 20 Packs/Case
    10-0502 50ml Plug Seal Yes Bulk 25 Sets/Pack, 20 Packs/Case
    10-0815 15ml Plug Seal No Bulk 500 Sets/Case
    10-0850 50ml Plug Seal No Bulk 500 Sets/Case

    15ml 50ml Flat Top Centrifuge Tubes Gamma Steriled and Non-Sterile Racked and Bulk Package

    15ml 50ml Flat Top Centrifuge Tubes Gamma Steriled and Non-Sterile Racked and Bulk Package
    15ml 50ml Flat Top Centrifuge Tubes Gamma Steriled and Non-Sterile Racked and Bulk Package

    15ml 50ml Flat Top Centrifuge Tubes Gamma Steriled and Non-Sterile Racked and Bulk Package
    1.What are the main factors that influence the maximum centrifugal acceleration force?
    Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
    The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
    Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

    2.What are autoclaving guidelines of plastics?
    To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

    3.What are Biologix's Commitments to Quality?
    We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 
     

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now
    Contact Supplier