• Self- Standing Sterile Cryogenic Vials Gamma Radiation Sterilized, Dnase & Rnase Free, Endotoxin Free, Foreign DNA Free
  • Self- Standing Sterile Cryogenic Vials Gamma Radiation Sterilized, Dnase & Rnase Free, Endotoxin Free, Foreign DNA Free
  • Self- Standing Sterile Cryogenic Vials Gamma Radiation Sterilized, Dnase & Rnase Free, Endotoxin Free, Foreign DNA Free

Self- Standing Sterile Cryogenic Vials Gamma Radiation Sterilized, Dnase & Rnase Free, Endotoxin Free, Foreign DNA Free

Disposable: Disposable
Certification: CE, ISO, ISO9001
Material: Plastic
Color of Caps: 7 Assorted Colors
Volume: 0.5 Ml/1.0ml/1.5ml/2.0ml/5.0ml
Sterilization: Pre-Sterile with Radiation
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
88-005X/88-010X/88-015X/88-020X/88-021X//88-050X
Packaging
25 /Bag, 40 Bags/Pack
Special Design
Designed and Tested for Cryoboxes
Pyrogenic
Certified Free of Pyrogen, Nucleases, Foreign DNA
Working Temperature
-196 C to 121c
Type
Vials
Transport Package
25 /Bag, 40 Bags/Pack
Trademark
Biologix Brand
Origin
Changzhou, Jiangsu

Product Description

Self- Standing Sterile Cryogenic Vials Gamma Radiation Sterilized, Dnase & Rnase Free, Endotoxin Free, Foreign DNA Free

Features
Made of medical grade polypropylene, can be repeatedly frozen and thawed
Vials have a white writing area and black graduations; 7 different colored caps are available
Gamma radiation sterilized, DNase & RNase free, endotoxin free, foreign DNA free

Specifications
Working temperature: stable from -196°C to 121°C
Suitable for liquid nitrogen freezing

Self- Standing Sterile Cryogenic Vials Gamma Radiation Sterilized, Dnase & Rnase Free, Endotoxin Free, Foreign DNA Free

Ordering Information

Cat#

Type

Volume

Bottom

Writing Area

Sterile

Unit

88-005X External Thread 0.5ml Self-Standing Yes Yes 25 /Bag, 40 Bags/Pack
88-010X External Thread 1.0ml Self-Standing Yes Yes 25 /Bag, 40 Bags/Pack
88-015X External Thread 1.5ml Self-Standing Yes Yes 25 /Bag, 40 Bags/Pack

88-020X

External Thread

2.0ml

Self-Standing

Yes

Yes

25 /Bag, 40 Bags/Pack

88-021X

Internal Thread

2.0ml

Self-Standing

Yes

Yes

25 /Bag, 40 Bags/Pack

88-050X

External Thread

5.0ml

Self-Standing

Yes

Yes

25 /Bag, 40 Bags/Pack

 

X: Cap Color    0-White, 1-Red, 2-Green, 3-Blue, 4-Yellow*, 5-Purple, 7-Clear

*Call for information

Self- Standing Sterile Cryogenic Vials Gamma Radiation Sterilized, Dnase & Rnase Free, Endotoxin Free, Foreign DNA Free

1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2.  What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3.  What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being FDA, ISO 9001:2015, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP