Laboratory Consumable 0.4/0.75/1.4ml External Thread PP Plastic SBS StandardCryogenic Vials
Feature:
· Three volumes: 0.4ml, 0.75ml and 1.4ml
· Vials: PP, autoclavable, 2-Color injection molding technique
· Four codes on one vial: Bottom: Laser etched 2D code and human-readable codes; Side: Laser etched 1D barcode and human-readable codes
· Racks: Side: Laser etched 1D barcode, 2D code, and human-readable codes; Bottom: 2D code. Pre-set alphanumeric marks for sample identification. Can be used with CKS-1301 CryoKING scanner to manager samples
· Gamma radiations sterilized; DNase & RNase free
· Stable from -196°C to 121°C, can be stored in vapor phase liquid nitrogen
· Compatible with Micronic cappers & decappers and sample management system
Ordering Information
Cat# |
Material |
Volume(ml) |
Code |
Rack Well |
Dimensions (mm) |
Unit |
89-514X |
PP |
0.4 |
Bottom code & side code |
96 |
128*85*56 |
10 Bags/Pack,2 Packs/Case |
89-504X |
PP |
0.75 |
Bottom code & side code |
96 |
128*85*32 |
10 Bags/Pack,2 Packs/Case |
89-508X |
PP |
1.4 |
Bottom code & side code |
96 |
128*85*39 |
10 Bags/Pack,2 Packs/Case |
X--Cap Color : 0-White* , 1-Red* , 2-Green* , 3-Blue , 4-Yellow* , 5-Purple*
* Call for information
1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc.