• Cryoking Cryogenic Vials-Side Barcodes & Human Readable Numbers 0.5ml 1.0ml 1.5ml 2.0ml 5.0ml Gamma Radiation Sterilized; Dnase & Rnase Free
  • Cryoking Cryogenic Vials-Side Barcodes & Human Readable Numbers 0.5ml 1.0ml 1.5ml 2.0ml 5.0ml Gamma Radiation Sterilized; Dnase & Rnase Free
  • Cryoking Cryogenic Vials-Side Barcodes & Human Readable Numbers 0.5ml 1.0ml 1.5ml 2.0ml 5.0ml Gamma Radiation Sterilized; Dnase & Rnase Free
  • Cryoking Cryogenic Vials-Side Barcodes & Human Readable Numbers 0.5ml 1.0ml 1.5ml 2.0ml 5.0ml Gamma Radiation Sterilized; Dnase & Rnase Free

Cryoking Cryogenic Vials-Side Barcodes & Human Readable Numbers 0.5ml 1.0ml 1.5ml 2.0ml 5.0ml Gamma Radiation Sterilized; Dnase & Rnase Free

Certification: CE, ISO, ISO9001
Capacity: 0.5ml, 1.0ml, 1.5ml, 2ml, 5ml
Working Temperature: -196 C to 121c
Design: White Writing Area and Black Graduations
Sterile: Gamma Radiation Sterilized
Volume: 0.5ml 1.0ml 1.5ml 2.0ml 5.0ml
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Other
Dnase & Rnase Free, Endotoxin , Foreign DNA Free
Transport Package
25 Sets/Bag, 40 Bags/Case
Specification
0.5ml 1.0ml 1.5ml 2.0ml 5.0ml
Trademark
CryoKING
Origin
Changzhou, Jiangsu

Product Description

CryoKING Cryogenic Vials-Side Barcodes & Human Readable Numbers
 

Cryoking Cryogenic Vials-Side Barcodes & Human Readable Numbers 0.5ml 1.0ml 1.5ml 2.0ml 5.0ml Gamma Radiation Sterilized; Dnase & Rnase Free
Cryoking Cryogenic Vials-Side Barcodes & Human Readable Numbers 0.5ml 1.0ml 1.5ml 2.0ml 5.0ml Gamma Radiation Sterilized; Dnase & Rnase Free


 

Cryoking Cryogenic Vials-Side Barcodes & Human Readable Numbers 0.5ml 1.0ml 1.5ml 2.0ml 5.0ml Gamma Radiation Sterilized; Dnase & Rnase Free
Cryoking Cryogenic Vials-Side Barcodes & Human Readable Numbers 0.5ml 1.0ml 1.5ml 2.0ml 5.0ml Gamma Radiation Sterilized; Dnase & Rnase Free


Features

--Made of medical grade polypropylene; Can be repeatedly frozen and thawed

--Self-Standing and external threads

--Vials have a white writing area and black graduations

--Side 1D barcode and human readable numbers, on one vial make identification more convenient than ever

--Gamma radiation sterilized; DNase & RNase free, endotoxin free, foreign DNA free

--Working temperature: stable from -196°C to 121°C

--Suitable for liquid nitrogen freezing
 

Ordering Information
 
Cat #

Volume

Thread Type

Bottom Barcode Writing Area Side Barcode Sterile Unit
88-605X 0.5ml

External

No Yes Yes Yes 25 Sets/Bag, 40 Bags/Case

88-610X

1.0ml

External

No Yes Yes Yes 25 Sets/Bag, 40 Bags/Case
88-615X 1.5ml

External

No Yes Yes Yes 25 Sets/Bag, 40 Bags/Case
88-721X 2.0ml

Internal

No Yes Yes Yes 25 Sets/Bag, 40 Bags/Case
88-720X 2.0ml

External

No Yes Yes Yes 25 Sets/Bag, 40 Bags/Case
88-750X 5.0ml

External

No Yes Yes Yes 25 Sets/Bag, 40 Bags/Case

X: Cap Color    0-White, 1-Red, 2-Green, 3-Blue, 4-Yellow*, 5-Purple, 7-Clear

*Call for information
Cryoking Cryogenic Vials-Side Barcodes & Human Readable Numbers 0.5ml 1.0ml 1.5ml 2.0ml 5.0ml Gamma Radiation Sterilized; Dnase & Rnase Free

1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP