• 15ml Centrifuge Tubes with Plug Seal (10-0151/0152) Free Rnase and Dnase
  • 15ml Centrifuge Tubes with Plug Seal (10-0151/0152) Free Rnase and Dnase
  • 15ml Centrifuge Tubes with Plug Seal (10-0151/0152) Free Rnase and Dnase
  • 15ml Centrifuge Tubes with Plug Seal (10-0151/0152) Free Rnase and Dnase
  • 15ml Centrifuge Tubes with Plug Seal (10-0151/0152) Free Rnase and Dnase

15ml Centrifuge Tubes with Plug Seal (10-0151/0152) Free Rnase and Dnase

Certification: CE, ISO
Material: PP Material
Capacity: 15mL
Cap: Plug Seal
Volume: 15ml and 50ml
Type: Centrifuge Tubes
Samples:
US$ 1/Piece 1 Piece(Min.Order)
| Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
10-0151/0152
Rnase/Dnase
Free
Transport Package
500/Case
Specification
PE material
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China
Production Capacity
200 Cases/Week

Product Description

Features
 

Tubes: made of strong, highly transparent medical grade polypropylene

Flat-top caps: made of medical grade polyethylene

Plug-seal screw on caps: made of medical grade polypropylene

15ml and 50ml conical tubes available; large white writing area for easy marking

Double threaded design reduces cross-threading; caps are easily opened and closed

Flat-top caps can be written on

Gamma radiation sterilized, non-pyrogenic

Available in racked package (sterile) or bulk package (sterile & non-sterile)

RNase & DNase free

 

Specifications

Working temperature: stable from -20°C to 121°C (except flat-top cap)

15ml and 50ml tubes can withstand centrifugation of 8,400 and 9,400 RCF

respectively

Sealing test: complies with The International Air Transport Association (IATA)

Safety Standards


Catalog #
 

Volume
 

Caps
 

Pack
 

Sterile
 

Unit
 

10-9151
 

15ml
 

Flat Top
 

Rack
 

Yes
 

50/rack, 500 /c ase
 

10-9152
 

15ml
 

Flat Top
 

Bulk
 

Yes
 

50 / bag, 500 / case
 

10-9501
 

50ml
 

Flat Top
 

Rack
 

Yes
 

25/rack, 500 / case
 

10-9502
 

50ml
 

Flat Top
 

Bulk
 

Yes
 

50/bag, 500/case
 

10-9815
 

15ml
 

Flat Top
 

Bulk
 

No
 

500/case
 

10-9850
 

50ml
 

Flat Top
 

Bulk
 

No
 

500/case
 

10-0151
 

15ml
 

Plug Seal
 

Rack
 

Yes
 

50/rack, 500 /c ase
 

10-0152
 

15ml
 

Plug Seal
 

Bulk
 

Yes
 

50 / bag, 500 / case
 

10-0501
 

50ml
 

Plug Seal
 

Rack
 

Yes
 

25/rack, 500/case
 

10-0502
 

50ml
 

Plug Seal
 

Bulk
 

Yes
 

50/bag, 500/case
 

10-0815
 

15ml
 

Plug Seal
 

Bulk
 

No
 

500/case
 

10-0850
 

50ml
 

Plug Seal
 

Bulk
 

No
 

500/case
 

10-0122
 

15ml
 

-
 

Bulk
 

No
 

1,000/case
 

10-0123
 

-
 

Press Cap
 

Bulk
 

No
 

1,000/case
 
 15ml Centrifuge Tubes with Plug Seal (10-0151/0152) Free Rnase and Dnase15ml Centrifuge Tubes with Plug Seal (10-0151/0152) Free Rnase and Dnase15ml Centrifuge Tubes with Plug Seal (10-0151/0152) Free Rnase and Dnase15ml Centrifuge Tubes with Plug Seal (10-0151/0152) Free Rnase and Dnase
  1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
  1. What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP