Laboratory Disposable Consumable 0.1/0.2ml Plastic PP Clear and White Flat/Dome Cap 8-Strips PCR Tubes

Product Details
Disposable: Disposable
Certification: CE, ISO
Reactant State: Liquid
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Laboratory Disposable Consumable 0.1/0.2ml Plastic PP Clear and White Flat/Dome Cap 8-Strips PCR Tubes
  • Laboratory Disposable Consumable 0.1/0.2ml Plastic PP Clear and White Flat/Dome Cap 8-Strips PCR Tubes
  • Laboratory Disposable Consumable 0.1/0.2ml Plastic PP Clear and White Flat/Dome Cap 8-Strips PCR Tubes
  • Laboratory Disposable Consumable 0.1/0.2ml Plastic PP Clear and White Flat/Dome Cap 8-Strips PCR Tubes
  • Laboratory Disposable Consumable 0.1/0.2ml Plastic PP Clear and White Flat/Dome Cap 8-Strips PCR Tubes
  • Laboratory Disposable Consumable 0.1/0.2ml Plastic PP Clear and White Flat/Dome Cap 8-Strips PCR Tubes
Find Similar Products

Basic Info.

Model NO.
60-0088 60-0188 60-0288 60-0388 60-0488 60-0008 6
Material
PP Material
Cap
Flat Top / Dome-Shaped
Tube
8-Strip
Qpcr
Flat Caps Are Ideal for Real-Time PCR (Qpcr)
Character
Faster Heating and Cooling
Dnase Rnase Free
Dnase Rnase and Endotoxin Free
Volume
0.1/0.2ml
Transport Package
125 Strip Tubes+125 Strip Caps/Bag/Pack, 10 Packs
Specification
0.2ml
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China

Product Description

Laboratory Disposable Consumable 0.1/0.2ml PP Clear and White Flat/Dome Cap 8-Strips PCR Tubes


Feature

· China 0.2ml 8-strip PCR Tube Suppliers

· Material: PP

· Easy for observation

· Domed caps ensure efficient heat transfer, while flat caps are ideal for Real-Time PCR(qPCR); unique design prevents opening during cycling and incubation

· Attached caps offer the option of opening and closing the tubes independently to prevent sample contamination.

· DNase, RNase, and endotoxin free

· Re-sealable plastic bags packed in individual boxes-keeping them contamination-free and easily stored

· Temperature range: stable from -20ºC to 100ºC

· Universal fits for the PCR instrument; withstand centrifugation of 6,000 RCF in a fully supported rotor

* Assorted colors for 8-Strip PCR tubes should be ordered separately
 

Laboratory Disposable Consumable 0.1/0.2ml Plastic PP Clear and White Flat/Dome Cap 8-Strips PCR Tubes
Laboratory Disposable Consumable 0.1/0.2ml Plastic PP Clear and White Flat/Dome Cap 8-Strips PCR Tubes
Ordering Information

Cat# Volume Color Cap High Transparency Unit
60-0088 0.2ml Clear Flat-top Yes 125 Sets/Pack, 10 Packs/Case
60-0188 0.2ml Pink Flat-top Yes 125 Sets/Pack, 10 Packs/Case
60-0388 0.2ml Blue Flat-top Yes 125 Sets/Pack, 10 Packs/Case
60-0488 0.2ml Yellow Flat-top Yes 125 Sets/Pack, 10 Packs/Case
60-0008 0.2ml Clear Dome-shaped Yes 125 Sets/Pack, 10 Packs/Case
60-0108 0.2ml Pink Dome-shaped Yes 125 Sets/Pack, 10 Packs/Case
60-0208 0.2ml Green Dome-shaped Yes 125 Sets/Pack, 10 Packs/Case
60-0308 0.2ml Blue Dome-shaped Yes 125 Sets/Pack, 10 Packs/Case
60-0408 0.2ml Yellow Dome-shaped Yes 125 Sets/Pack, 10 Packs/Case
60-1088 0.1ml Clear Tubes, Clear Caps Flat-top Yes 125 Sets/Pack, 10 Packs/Case
60-1088W 0.1ml White Tubes, Clear Caps Flat-top Yes 125 Sets/Pack, 10 Packs/Case
60-0288 0.2ml Clear tubes Individual type with attached cap, flat-top Yes 120/Unit, 10 Units/Case


Laboratory Disposable Consumable 0.1/0.2ml Plastic PP Clear and White Flat/Dome Cap 8-Strips PCR Tubes1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2. What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3. What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier