• 6/12/24/48/96-Well Laboratory Consumables Polystyrene Tc Treated Cell Culture Plates
  • 6/12/24/48/96-Well Laboratory Consumables Polystyrene Tc Treated Cell Culture Plates
  • 6/12/24/48/96-Well Laboratory Consumables Polystyrene Tc Treated Cell Culture Plates
  • 6/12/24/48/96-Well Laboratory Consumables Polystyrene Tc Treated Cell Culture Plates
  • 6/12/24/48/96-Well Laboratory Consumables Polystyrene Tc Treated Cell Culture Plates
  • 6/12/24/48/96-Well Laboratory Consumables Polystyrene Tc Treated Cell Culture Plates

6/12/24/48/96-Well Laboratory Consumables Polystyrene Tc Treated Cell Culture Plates

After-sales Service: 3 Years
Warranty: 3 Years
Disposable: Disposable
Certification: CE, ISO, ISO9001
Reactant State: Liquid
Material: Rubber / Plastic
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
07-6006/07-6012/07-6024/07-6048/07-6096
Sterile
Yes
Size
6 Wells, 12 Well, 24 Wells, 48 Well, 96 Wells
Sterilized
Electron Beam Sterilized
Wells
6-Well, 12-Well, 24-Well, 48-Well, 96-Well
External Dimensions
85.40*127.6*20.20, 85.4*127.6*14.40
Working Volume
3ml, 2ml, 1ml, 0.5ml, 0.2ml
Transport Package
1/5
Specification
6 wells, 24 wells, 96 wells
Trademark
BIOLOGIX
Origin
America
Production Capacity
100000 Cases/Month

Product Description

6/12/24/48/96-Well Laboratory Consumables Polystyrene TC Treated Cell Culture Plates

Feature:
· TC Treated 6/12/24/48/96-Well Cell Culture Plates
· 6/12/24/48/96-well plates are available
· Constructed of prime virgin polystyrene
· Plate cover design minimizes the risk of cross contamination
· Thin-walled well bottoms increase thermal consistency, reducing the edge effect
· Flat well bottoms provide excellent clarity for microscopic examination of samples
· Raised well rim design around each well enables secure sealing and safeguards against evaporation
· Gamma radiation sterilized
· Non-pyrogenic, non-cytotoxic
· DNase & RNase free, human DNA free
· TC treated

6/12/24/48/96-Well Laboratory Consumables Polystyrene Tc Treated Cell Culture Plates
6/12/24/48/96-Well Laboratory Consumables Polystyrene Tc Treated Cell Culture Plates
Ordering Information

Cat # Wells

External Dimensions

W x Lx H (mm)

Well Dimensions

Dx H (mm)

Culture

Area

Working

Volume

Full Volume Sterile Unit
07-6006 6-well 85.4x127.6x20.2mm 35x17.5mm 9.6cm2 3ml 16.8 YES

1 Piece/Pack, 50 Packs/Case

07-6012 12-well 85.4x127.6x20.2mm 21.9x17.5mm 3.8cm2 2ml 6.6 YES

1 Piece/Pack, 50 Packs/Case

07-6024 24-well 85.4x127.6x20.2mm 15.5x17.5mm 1.9cm2 1ml 3.3 YES

1 Piece/Pack, 50 Packs/Case

07-6048 48-well 85.4x127.6x20.2mm 9.75x17.5mm 0.75cm2 0.5ml 1.33 YES

1 Piece/Pack, 50 Packs/Case

07-6096 96-well 85.4x127.6x14.4mm 6.5x10.8mm 0.33cm2 0.2ml 0.33 YES

1 Piece/Pack, 50 Packs/Case


6/12/24/48/96-Well Laboratory Consumables Polystyrene Tc Treated Cell Culture Plates

 
1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2. What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE-Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3. What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers' lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP