Warranty: | No |
---|---|
Disposable: | Disposable |
Certification: | CE, ISO, FDA |
Still deciding? Get samples of US$ 0/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Laboratory Disposable Plastic PP 1.4ml Cryogenic Vials 96-Well Format External Thread Sterile Liquid Nitrogen Low Temperature Freezing Storage Tubes
Compatible with Micronic cappers & decappers and sample management system
1. Vials are made of medical grade polypropylene; racks are made of polycarbonate. Autoclavable, and can be repeatedly frozen and thawed.
2. 4 coded vials and multi-coded rack enable excellent sample management & traceability.
3. Secure locking function enables safe sample storage.
4. Standard ANSI / SLAS format perfectly fits automatic operations.
5. RNase & DNase Free, Endotoxin Free, Foreign DNA Free
Specifications
1. Working temperature: stable from -196°C to 121°C .
2. Suitable for liquid nitrogen freezing(gas phase).
Cat # | Description | Unit |
88-514X | Vials, 1.4ml, external thread, blue caps; Self-Standing; 2-color injection molding technique; Laser-etched 4 codes. Gamma radiation sterilized. | 96 Vials/Bag, 20 Bags/Case(1920 Vials/Case) |
98-5227 | Racks, for 1.4ml external vials; 96-well; Square holes, White; Dimensions(mm): 128x85x56. | 10 Rack/Pack, 2 Packs/Case(20 Racks/Case) |
89-514X | Combo, 1.4ml vials + rack; Dimensions(mm): 128x85x56. Gamma radiation sterilized. | 1 Set/Bag ,10 Bags/Pack, 2 Packs/Case(1920 Vials + 20 Packs/Case) |
Laboratory Disposable Plastic PP 1.4ml Cryogenic Vials 96-Well Format External Thread Sterile Liquid Nitrogen Low Temperature Freezing Storage Tubes
1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc.