Lab Consumable Polystyrene Tc/Non-Tc Treated Dnase & Rnase Free Sterile Cell Culture Dishes

Product Details
Warranty: 3 Years
Customized: Non-Customized
Structure: Other
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Lab Consumable Polystyrene Tc/Non-Tc Treated Dnase & Rnase Free Sterile Cell Culture Dishes
  • Lab Consumable Polystyrene Tc/Non-Tc Treated Dnase & Rnase Free Sterile Cell Culture Dishes
  • Lab Consumable Polystyrene Tc/Non-Tc Treated Dnase & Rnase Free Sterile Cell Culture Dishes
  • Lab Consumable Polystyrene Tc/Non-Tc Treated Dnase & Rnase Free Sterile Cell Culture Dishes
  • Lab Consumable Polystyrene Tc/Non-Tc Treated Dnase & Rnase Free Sterile Cell Culture Dishes
Find Similar Products

Basic Info.

Model NO.
07-3035/07-3060/07-3100/07-3150
Material
Plastic
Certification
CE, ISO, FDA
Application
School, Hospital, Lab, Collection and Transportation of Clinical Flu. etc
Type
Culturing
Name
Made of Polystyrene Tc Treated Dnase & Rnase Free
Size
35*10, 60*15, 90*20, 150*25 mm
Color
Clear
Treated
Tc Treated & Non-Tc Treated
Sterilized
Electron Beam Sterilized
Working Volume
3.00 Ml, 5.00ml, 12.50ml, 35.00 Ml
Specification
10/20
Trademark
Biologix
Origin
America
Production Capacity
1000000 Cases/Month

Packaging & Delivery

Package Size
10.00cm * 10.00cm * 12.00cm
Package Gross Weight
6.000kg

Product Description

Made of Polystyrene TC Treated DNase & RNase Free Cell Culture Dishes

Feature:

· TC Treated DNase & RNase Free Cell Culture Dishes
· Cell culture dishes are made of high quality medical grade polystyrene
· Four sizes are available: 9.4cm2 , 21.5cm2, 57.5cm2, and 148cm2
· Electron beam sterilized
· DNase & RNase free, human DNA free
· Lid design promotes effective gas exchange
· External grip for easier handling
· Raised edges for convenient stacking
· Vacuum plasma surface treatment ensures excellent cell adhesion
· Smooth, transparent materials facilitate observation of cells through a microscope
· Non-pyrogenic, non-cytotoxic
· TC treated

Lab Consumable Polystyrene Tc/Non-Tc Treated Dnase & Rnase Free Sterile Cell Culture Dishes
Lab Consumable Polystyrene Tc/Non-Tc Treated Dnase & Rnase Free Sterile Cell Culture Dishes
Ordering Information

Cat # Dish Style (DxH) Internal Dimensions (DxH) Culture Area Working Volume External Grip TC Treated Sterile Unit
07-3035 35x10mm 34.3x9.3mm 9.4cm2 3ml Yes  Yes Yes  10/Bag, 50 Bags/Case
07-3060 60x15mm 52.8x12.8mm 21.5cm2 5ml Yes Yes Yes 10/Bag, 50 Bags/Case
07-3100 90x20mm 86.26x17.7mm 57.5cm2 12.5ml No Yes Yes  10/Bag, 20 Bags/Case
07-3150 150x25mm 140.2×23.3mm 148cm2 35ml No Yes Yes 10/Bag, 12 Bags/Case

 

Lab Consumable Polystyrene Tc/Non-Tc Treated Dnase & Rnase Free Sterile Cell Culture Dishes1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2. What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3. What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier