Lab Consumables 20μ L, 200μ L, 300μ L, 1000μ L, and 1200μ L Tips PP Material Low Retention Lts Pipette

Product Details
Warranty: No
Disposable: Disposable
Certification: CE, ISO, FDA
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Lab Consumables 20μ L, 200μ L, 300μ L, 1000μ L, and 1200μ L Tips PP Material Low Retention Lts Pipette
  • Lab Consumables 20μ L, 200μ L, 300μ L, 1000μ L, and 1200μ L Tips PP Material Low Retention Lts Pipette
  • Lab Consumables 20μ L, 200μ L, 300μ L, 1000μ L, and 1200μ L Tips PP Material Low Retention Lts Pipette
  • Lab Consumables 20μ L, 200μ L, 300μ L, 1000μ L, and 1200μ L Tips PP Material Low Retention Lts Pipette
  • Lab Consumables 20μ L, 200μ L, 300μ L, 1000μ L, and 1200μ L Tips PP Material Low Retention Lts Pipette
  • Lab Consumables 20μ L, 200μ L, 300μ L, 1000μ L, and 1200μ L Tips PP Material Low Retention Lts Pipette
Find Similar Products

Basic Info.

Model NO.
R23-0020/R23-0021/R23-020/R23-0201/R23-0300
Reactant State
Liquid
Material
PP
Color
Clear Lts Pipette Tips
Sterile
Sterile Lts Pipette Tips
Dnase Rnase Free
Dnase Rnase Free Tips
Low Retention
Yes
Volume
20/200/300/1000/1200μl
Package
96 Tips/Rack, 50 Racks/Case
Transport Package
96 Tips/Rack, 50 Racks/Case
Specification
20ul 200ul and 1000ul tips
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China
Production Capacity
100000 Cases/Week

Product Description

Lab Consumables 20μl, 200μl, 300μl, 1000μl, and 1200μl Tips PP Material Low Retention LTS Pipette


Feature:

· LTS Pipette Tips
· Tips are made of medical grade polypropylene, autoclavable, and filters are made of highly hydrophobic UHMWPE
· 20μl, 200μl, 300μl, 1000μl, and 1200μl tips
· Filters prevent cross-contamination and damage to samples, ensure accurate and precise sample aspiration, and protect the user by preventing · sample liquid or vapor from entering the pipette body
· Low-retention tips undergo a coating-free treatment and will not contaminate samples
· User-friendly labels on tip racks enable convenient usage
· DNase & RNase Free, non-pyrogen
· Sterile SAL 10-6


Lab Consumables 20μ L, 200μ L, 300μ L, 1000μ L, and 1200μ L Tips PP Material Low Retention Lts Pipette
Lab Consumables 20μ L, 200μ L, 300μ L, 1000μ L, and 1200μ L Tips PP Material Low Retention Lts Pipette
Ordering Information

Cat# Volume Sterile Low Retention Unit Total
R23-0020 20μl Yes No 96 Tips/Rack, 50 Racks/Case 4800 Tips/Case
R23-0021 20μl Yes Yes 96 Tips/Rack, 50 Racks/Case 4800 Tips/Case
R23-0200 200μl Yes No 96 Tips/Rack, 50 Racks/Case 4800 Tips/Case
R23-0201 200μl Yes Yes 96 Tips/Rack, 50 Racks/Case 4800 Tips/Case
R23-0300 300μl Yes No 96 Tips/Rack, 50 Racks/Case 4800 Tips/Case
R23-0301 300μl Yes Yes 96 Tips/Rack, 50 Racks/Case 4800 Tips/Case
R23-1000 1000μl Yes No 96 Tips/Rack, 50 Racks/Case 4800 Tips/Case
R23-1001 1000μl Yes Yes 96 Tips/Rack, 50 Racks/Case 4800 Tips/Case
R23-1200 1200μl Yes No 96 Tips/Rack, 50 Racks/Case 4800 Tips/Case
R23-1201 1200μl Yes Yes 96 Tips/Rack, 50 Racks/Case 4800 Tips/Case

 

Lab Consumables 20μ L, 200μ L, 300μ L, 1000μ L, and 1200μ L Tips PP Material Low Retention Lts Pipette1. What are the main factors that influence the maximum centrifugal acceleration force?

Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?

We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier