Laboratory Consumable Plasitc PC 25/81/100-Well 1/2/3.75 Inch Cryogenic Boxes Storage Low Temperature Freezing Boxes

Product Details
Disposable: Non-Disposable
Certification: CE, ISO
Reactant State: Solid
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Laboratory Consumable Plasitc PC 25/81/100-Well 1/2/3.75 Inch Cryogenic Boxes Storage Low Temperature Freezing Boxes
  • Laboratory Consumable Plasitc PC 25/81/100-Well 1/2/3.75 Inch Cryogenic Boxes Storage Low Temperature Freezing Boxes
  • Laboratory Consumable Plasitc PC 25/81/100-Well 1/2/3.75 Inch Cryogenic Boxes Storage Low Temperature Freezing Boxes
  • Laboratory Consumable Plasitc PC 25/81/100-Well 1/2/3.75 Inch Cryogenic Boxes Storage Low Temperature Freezing Boxes
  • Laboratory Consumable Plasitc PC 25/81/100-Well 1/2/3.75 Inch Cryogenic Boxes Storage Low Temperature Freezing Boxes
  • Laboratory Consumable Plasitc PC 25/81/100-Well 1/2/3.75 Inch Cryogenic Boxes Storage Low Temperature Freezing Boxes
Find Similar Products

Basic Info.

Model NO.
90-9009/90-9210/90-9250/90-9381/-0200
Material
Rubber / Plastic
Height
1/2/3.75 Inch
Well
25/81/100-Well
Divider Material
PC
Dimensions (mm)
75X75X52
Unit
5 Pieces/Pack, 4 Packs/Case
Working Temperature
-196°c to 121°c
Transport Package
Case
Specification
30 /Case
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China
HS Code
3923100090
Production Capacity
200 Cases/Week

Product Description

Laboratory Consumable Plasitc PC 25/81/100-well 1/2/3.75 inch Cryogenic Boxes

Feature:
· 81-well And 100-well PC Cryongeic Boxes Cardboard Cryogenic Boxes
· Material: PC, chemically resistant to alcohols and mild organic solvents
· Can be repeatedly frozen and thawed
· Boxes has three sizes: 25-well, 81-well, and 100-well
· Compatible with 0.5ml, 1.0ml, 1.5ml, 2.0ml or 5.0ml microtubes and cryogenic vials
· Numbered grids for sample identification
· Drain holes and air vents minimize condensation
· Five assorted colors available
· Suitable for storage in freezers or liquid nitrogen(vapor phase)
· Working temperature: stable from -196°C to 121°C


Laboratory Consumable Plasitc PC 25/81/100-Well 1/2/3.75 Inch Cryogenic Boxes Storage Low Temperature Freezing Boxes
Laboratory Consumable Plasitc PC 25/81/100-Well 1/2/3.75 Inch Cryogenic Boxes Storage Low Temperature Freezing Boxes
Ordering Information
Cat # Height Wells Color Dimensions (mm) Unit Total
90-9009 2 in 81-well Assorted Colors 133x133x53 5/Bag,4 Bags/Case 20/Case
90-9210 2 in 100-well Assorted Colors 133x133x53 5 /Bag,4 Bags/Case 20/Case
90-9250 2 in 25-well Assorted Colors 75x75x53 5/Bag,6 Bags/Case 30/Case
90-9381 3.75 in 81-well Assorted Colors 133x133x95 5 /Bag,4 Bags/Case 20/Case
98-0113 1 in 100-well Blue 133x133x36 3/Bag,4 Bags/Case 12/Case
98-0200 2 in 100-well Blue 136x136x53 3/Bag,4 Bags/Case 12/Case
98-0213 2 in 100-well Blue 133x133x53 3/Bag,4 Bags/Case 12/Case
98-0313 3.75 in 81-well Blue 133x133x95 3/Bag,4 Bags/Case 12/Case
98-1213 2 in 81-well Blue 133x133x53 3/Bag,4 Bags/Case 12/Case

 

Laboratory Consumable Plasitc PC 25/81/100-Well 1/2/3.75 Inch Cryogenic Boxes Storage Low Temperature Freezing Boxes1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2.  What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3.  What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier