Laboratory Consumable Micro 0.2ml Flat-Top/Dome-Shaped PCR Single Tubes

Product Details
Disposable: Disposable
Certification: CE, ISO, FDA
Reactant State: Liquid
Still deciding? Get samples of US$ 0/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Laboratory Consumable Micro 0.2ml Flat-Top/Dome-Shaped PCR Single Tubes
  • Laboratory Consumable Micro 0.2ml Flat-Top/Dome-Shaped PCR Single Tubes
  • Laboratory Consumable Micro 0.2ml Flat-Top/Dome-Shaped PCR Single Tubes
  • Laboratory Consumable Micro 0.2ml Flat-Top/Dome-Shaped PCR Single Tubes
  • Laboratory Consumable Micro 0.2ml Flat-Top/Dome-Shaped PCR Single Tubes
  • Laboratory Consumable Micro 0.2ml Flat-Top/Dome-Shaped PCR Single Tubes
Find Similar Products

Basic Info.

Model NO.
60-0088 60-0188 60-0288 60-0388 60-0488 60-0008
Material
Rubber / Plastic
Color
Clear Pink Green Blue Yellow
Vocume
0.2ml
Working Temperature
Stable From -20ºC to 100ºC
Cap Type
Flat/Domed
Transport Package
1000/Bag/Pack, 10 Packs/Case
Specification
0.2ml PCR tubes
Trademark
Biologix
Origin
China

Packaging & Delivery

Package Size
24.00cm * 12.00cm * 9.00cm
Package Gross Weight
7.000kg

Product Description

Laboratory Consumable Micro 0.2ml Flat-Top/Dome-Shaped PCR Single Tubes

Feature:

· 0.2mL Flat Cap PCR Single Tubes

· Material: prime virgin polypropylene

· Domed caps transfer heat faster, while flat caps are ideal for real-time PCR (qPCR);

· Single PCR tube has high transparency and a very thin wall, making it easy to observe and conduct heat during the experiment.

· Unique cap design prevents opening during cycling and incubation

· DNase, RNase, and endotoxin free

· Working Temperature: stable from -20ºC to 100ºC

· Universal fits for the PCR instrument; Withstand centrifugation of 6,000 RCF in a fully supported rotor

* Assorted colors for PCR tubes should be ordered separately

Laboratory Consumable Micro 0.2ml Flat-Top/Dome-Shaped PCR Single Tubes

Laboratory Consumable Micro 0.2ml Flat-Top/Dome-Shaped PCR Single Tubes

Ordering Information

Cat # Volume Color Cap Sterile Unit
60-0082 0.2ml Clear Flat-top NO 1,000/Pack, 10 Bags/case

60-0182

0.2ml Pink Flat-top NO 1,000/Pack, 10 Bags/case

60-0282

0.2ml Green Flat-top NO 1,000/Pack, 10 Bags/case

60-0382

0.2ml Blue Flat-top NO 1,000/Pack, 10 Bags/case

60-0482

0.2ml Yellow Flat-top NO 1,000/Pack, 10 Bags/case
60-0002 0.2ml Clear Dome-shaped NO 1,000/Pack, 10 Bags/case
60-0102 0.2ml Pink Dome-shaped NO 1,000/Pack, 10 Bags/case
60-0202 0.2ml Green Dome-shaped NO 1,000/Pack, 10 Bags/case
60-0302 0.2ml Blue Dome-shaped NO 1,000/Pack, 10 Bags/case
60-0402 0.2ml Yellow Dome-shaped NO 1,000/Pack, 10 Bags/case


Laboratory Consumable Micro 0.2ml Flat-Top/Dome-Shaped PCR Single Tubes1.What are the main factors that influence the maximum centrifugal acceleration force?

Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?

To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier