• Laboratory Consumables Pre-Sterilized by Gamma Irradiation Vacuum Filtration Unit-Funnel
  • Laboratory Consumables Pre-Sterilized by Gamma Irradiation Vacuum Filtration Unit-Funnel
  • Laboratory Consumables Pre-Sterilized by Gamma Irradiation Vacuum Filtration Unit-Funnel
  • Laboratory Consumables Pre-Sterilized by Gamma Irradiation Vacuum Filtration Unit-Funnel
  • Laboratory Consumables Pre-Sterilized by Gamma Irradiation Vacuum Filtration Unit-Funnel
  • Laboratory Consumables Pre-Sterilized by Gamma Irradiation Vacuum Filtration Unit-Funnel

Laboratory Consumables Pre-Sterilized by Gamma Irradiation Vacuum Filtration Unit-Funnel

Certification: CE, ISO, RoHS, FDA
Material: PS /Glass/PP
Sterile: Steriled by Gamma Irradiation
Pore Size: 0.22 μm
Funnel Volume: 500 Ml
Receiver Volume: 500ml
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
09-PES2250/09-PES2250F/09-CA2250/08-PES3322S
Membrane
Pes
Diameter
90/33 mm
Transport Package
12/24 Case
Specification
CE, FDA, ISO9001
Trademark
BIOLOGIX
Origin
Changzhou, Jiangsu, China

Product Description

Laboratory Consumables Pre-sterilized By Gamma Irradiation Vacuum Filtration Unit-Funnel

Feature:
· Disposable and pre-sterilized by gamma irradiation for rapid and convenient use.

· Wide base provides stability during use.

· Sterile graded 0.2um membrane: LRV>7 for Brevundimonas diminuta, ATCC19146.

· Non-pyrogenic, low extractables and surfactant-free ensures purity of filtrate.

· Engineered support structure maximizes flow rate and throughput.

· Available with 250 and 500mL filter funnels, and 250, 500 and 1000mL receiver bottles to meet various filtered volume requirements.

· Reservoir has textured areas for improved grip when handling and opening and sealing the bottle.

· GL45 threads accepts commonly used bottle style.


Laboratory Consumables Pre-Sterilized by Gamma Irradiation Vacuum Filtration Unit-Funnel
Laboratory Consumables Pre-Sterilized by Gamma Irradiation Vacuum Filtration Unit-Funnel

Ordering Information
Cat # Description Unit
09-PES2250 Vacuum filtration unit, membrane: PES, pore size: 0.22μm, diameter:90mm, funnel volume: 500ml, receiver volume: 500ml.  12
09-PES2250F Vacuum filtration unit-funnel, membrane: PES, pore size: 0.22μm, diameter:90mm, funnel volume: 500ml.  24
09-CA2250 Vacuum filtration unit-funnel, membrane: CA, pore size: 0.22μm, diameter:90mm, funnel volume: 500ml, receiver volume: 500ml.    12
08-PES3322S Membrane: PES, pore size: 0.22μm, diameter:33mm. Double luer lock.  Individually packed. 24

 

Laboratory Consumables Pre-Sterilized by Gamma Irradiation Vacuum Filtration Unit-Funnel1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP