20UL Filter Tips Rnase&Dnase Free Sterile Rack Pack Extra-Long

Product Details
Disposable: Disposable
Certification: CE, ISO, FDA Eo
Material: PP
Still deciding? Get samples of US$ 0/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • 20UL Filter Tips Rnase&Dnase Free Sterile Rack Pack Extra-Long
  • 20UL Filter Tips Rnase&Dnase Free Sterile Rack Pack Extra-Long
  • 20UL Filter Tips Rnase&Dnase Free Sterile Rack Pack Extra-Long
  • 20UL Filter Tips Rnase&Dnase Free Sterile Rack Pack Extra-Long
  • 20UL Filter Tips Rnase&Dnase Free Sterile Rack Pack Extra-Long
Find Similar Products

Basic Info.

Model NO.
20ul
Color
Tips All Are Natural Clear Color
Size
10UL 100UL 200UL 1000UL
Filters
Filters Are Made of UHMWPE with Pore Size 0.22um.
Transport Package
100 Racks/Case
Specification
CE, FDA, ISO9001
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China
Production Capacity
200 Cases/Week

Product Description

20ul filter tips with RNase&DNase free in stock low retention
20UL Filter Tips Rnase&Dnase Free Sterile Rack Pack Extra-Long
20UL Filter Tips Rnase&Dnase Free Sterile Rack Pack Extra-Long
20UL Filter Tips Rnase&Dnase Free Sterile Rack Pack Extra-Long

Characteristic
 

 Tips are made of PP, filters are made of UHMWPE with pore size 0.22um. 

 Tips all are natural clear color

 10µl, 20µl, 100µl, 200µl, and 1000µl tip sizes available.
 Filters prevent cross-contamination and damage to samples, ensure accurate and precise sample.
 Sterile.
 RNase & DNase free.

    Ordering Information
     
     22-0010  10µl Filter Tips, bulk pack, tip material: DNase & RNase Free, PP, filter material: UHMWPE. Filter diameter: 1.6mm, thickness: 3.5mm, 1000 Pieces/Bag, 10 Bags/Case
     22-0011  10µl Filter Tips, bulk pack, low retention, tip material: DNase & RNase Free,PP, filter material:  UHMWPE. Filter diameter: 1.6mm, thickness: 3.5mm, 1000 Pieces/Bag, 10 Bags/Case
     22-0200  200µl  Filter Tips, bulk pack, tip material: DNase & RNase Free,PP, filter material: UHMWPE. Filter diameter: 4.5mm, thickness: 3.5mm ,1000 Pieces/Bag, 10 Bags/Case
     22-0201  200µl  Filter Tips, bulk pack, low retention, tip material: DNase & RNase Free,PP, filter material:  UHMWPE. Filter diameter: 4.5mm, thickness: 3.5mm, 1000 Pieces/Bag, 10 Bags/Case
     22-1000  1000µl  Filter Tips, bulk pack, tip material: DNase & RNase Free,PP, filter material: UHMWPE. Filter diameter: 7.0mm, thickness: 4.2mm, 1000 Pieces/Bag, 10 Bags/Case
     22-1001  1000µl  Filter Tips, bulk pack, low retention, tip material: DNase & RNase Free,PP, filter material:  UHMWPE. Filter diameter:7.0mm, thickness: 4.2mm, 1000 Pieces/Bag, 10 Bags/Case
     


    20UL Filter Tips Rnase&Dnase Free Sterile Rack Pack Extra-Long20UL Filter Tips Rnase&Dnase Free Sterile Rack Pack Extra-Long20UL Filter Tips Rnase&Dnase Free Sterile Rack Pack Extra-Long20UL Filter Tips Rnase&Dnase Free Sterile Rack Pack Extra-Long

    1.What are the main factors that influence the maximum centrifugal acceleration force?
    Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
    The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
    Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

    2.What are autoclaving guidelines of plastics?

    To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

    3.What are Biologix's Commitments to Quality?
    We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now
    Contact Supplier