• PP, PS, and K-Resin Bulk/Tray Package, Narrow and Wide Drosophila Vials
  • PP, PS, and K-Resin Bulk/Tray Package, Narrow and Wide Drosophila Vials
  • PP, PS, and K-Resin Bulk/Tray Package, Narrow and Wide Drosophila Vials
  • PP, PS, and K-Resin Bulk/Tray Package, Narrow and Wide Drosophila Vials
  • PP, PS, and K-Resin Bulk/Tray Package, Narrow and Wide Drosophila Vials
  • PP, PS, and K-Resin Bulk/Tray Package, Narrow and Wide Drosophila Vials

PP, PS, and K-Resin Bulk/Tray Package, Narrow and Wide Drosophila Vials

Disposable: Disposable
Certification: CE, ISO
Material: PS/PP/K-Resin
Type: Vials
Description: Narrow/ Wide
Size (mm): 25X95 28.5X95
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
51-0500/51-0510/51-0520/51-0800/51-0810/51-0820
Sterile
No
Package
Bulk/ Tray
Unit 1
25/Bag, 20 Bags/Case
Unit 2
100/Tray, 5 Trays/Case
Transport Package
500/Case
Specification
25/Bag, 20 Bags/case
Trademark
BIOLOGIX
Origin
China
HS Code
3917290000

Product Description

PP, PS, and K-Resin Bulk/Tray Package, Narrow and Wide Drosophila Vials

Feature:

· PS/PP/K-Resin Drosophila Vials

· Made of Premium grade polypropylene, polystyrene, and K-Resin

· Polypropylene: firm, clear, flexible, corrosion resistant, and fully autoclavable(121°C, 15psi, 15min)

· Polystyrene: highly transparent and are conducive to sunlight exposure, easy to observe and store, cost-effective

· K-Resin: High transparency, good toughness, and can be sterilized by ethylene oxide gas or ultraviolet rays

· Durable and suitable for drosophila growth and development in most situations

· Disposable vials are safe and cost-effective alternative to glass vials

· Can be sterilized with ethylene oxide gas or ultraviolet rays and are suitable for observing the growth and development of the drosophila

· Disposable vials are safe and cost-effective alternative to glass vials

· Available in bulk or tray packing

· Tray packs are grate for quick, effortless filling of vials

· Bulk or tray packaging, and trays are available

· Vials combo format: 10*10


PP, PS, and K-Resin Bulk/Tray Package, Narrow and Wide Drosophila Vials
PP, PS, and K-Resin Bulk/Tray Package, Narrow and Wide Drosophila Vials

Ordering Information

Cat #

Product

Material

Size(Mm)

Unit

Total

51-0500 Narrow Vials PS 25*95 25/Bag, 20 Bags/case 500
51-0510 Narrow Vials PP 25*95 25/Bag, 20 Bags/case 500
51-0520 Narrow Vials K-Resin 25*95 25/Bag, 20 Bags/case 500
51-0800 Wide Vials PS 28.5*95 25/Bag, 20 Bags/case 500
51-0810 Wide Vials PP 28.5*95 25/Bag, 20 Bags/case 500
51-0820 Wide Vials K-Resin 28.5*95 25/Bag, 20 Bags/case 500
51-0501 Narrow Vials Combo PS 25*95 100/Tray, 5 Trays/Case 500
51-0511 Narrow Vials Combo PP 25*95 100/Tray, 5 Trays/Case 500
51-0521 Narrow Vials Combo K-Resin 25*95 100/Tray, 5 Trays/Case 500
51-0801 Wide Vials Combo PS 28.5*95 100/Tray, 5 Trays/Case 500
51-0811 Wide Vials Combo PP 28.5*95 100/Tray, 5 Trays/Case 500
51-0821 Wide Vials Combo K-Resin 28.5*95 100/Tray, 5 Trays/Case 500

PP, PS, and K-Resin Bulk/Tray Package, Narrow and Wide Drosophila Vials1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2. What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3. What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP