2D Barcode and Human-Readable Numbers SBS Format Cryogenic Racks Automatic Operations Liquid Nitrogen Freezing
Features
2D barcode and human-readable numbers on the side of SBS format racks; 2D barcode at the bottom of racks, cryogenic vials and racks can be traced at the same time.
Simple yet powerful mechanical locking function and slide the buttons on both sides to unlock .
Laser etched 2D barcodes, resistant to DMSO and other organic solvents .
SBS format rack fits 96-well format cryogenic vials perfectly for automatic operations .
Specifications
Working temperature: stable from -196°C to 121°C .
Suitable for liquid nitrogen freezing.
Cat # | Vial Volume | Wells | Dimensions(mm) | Unit |
98-4117A | 300μl & 500μl | 96-well, round | 128x85x35 | 10 /Pack , 2 Packs/Case |
98-4217A | 750μl & 1000μl | 96-well, round | 128x85x54 | 10 /Pack , 2 Packs/Case |
98-4127A | 300μl & 500μl | 96-well, square | 128x85x35 | 10 /Pack , 2 Packs/Case |
98-4227A | 750μl & 1000μl | 96-well, square | 128x85x54 | 10 /Pack , 2 Packs/Case |
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc.