L-Shape Cell Spreaders Smooth Surface Quality and Angled End

Product Details
Disposable: Disposable
Certification: CE, ISO, FDA
Color: Orange
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • L-Shape Cell Spreaders Smooth Surface Quality and Angled End
  • L-Shape Cell Spreaders Smooth Surface Quality and Angled End
Find Similar Products

Basic Info.

Model NO.
65-1001 65-1010
Transport Package
1 /Bag, 500 Bags/Case 10 /Bag, 50 Bags/Case
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China

Product Description

L-Shape Cell Spreaders Smooth Surface Quality and Angled End

Features

Polystyrene
Smooth surface quality and angled end reduce the risk of damaging the culture medium
L-shape allows application on the entire Culture Dish or plate surface
Two package options: individually wrapped (sterile), or 10 per bag (sterile, resealable)
Gamma radiation sterilized
L-Shape Cell Spreaders Smooth Surface Quality and Angled End
 
Ordering Information
 
Cat # Color Sterile Unit
65-1001 Orange YES 1 /Bag, 500 Bags/Case
65-1010 Orange YES 10 /Bag, 50 Bags/Case


L-Shape Cell Spreaders Smooth Surface Quality and Angled End1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2.  What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3.  What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being FDA, ISO 9001:2015, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier