Laboratory Consumables 0.1/0.2 Ml 96-Well Full-Skirt, Half-Skirt/Non-Skirt PCR Plates

Product Details
Transport Package: 25 Plates/Pack, 4 Packs/Case
Specification: CE, FDA, ISO
Trademark: Biologix
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Laboratory Consumables 0.1/0.2 Ml 96-Well Full-Skirt, Half-Skirt/Non-Skirt PCR Plates
  • Laboratory Consumables 0.1/0.2 Ml 96-Well Full-Skirt, Half-Skirt/Non-Skirt PCR Plates
  • Laboratory Consumables 0.1/0.2 Ml 96-Well Full-Skirt, Half-Skirt/Non-Skirt PCR Plates
  • Laboratory Consumables 0.1/0.2 Ml 96-Well Full-Skirt, Half-Skirt/Non-Skirt PCR Plates
  • Laboratory Consumables 0.1/0.2 Ml 96-Well Full-Skirt, Half-Skirt/Non-Skirt PCR Plates
  • Laboratory Consumables 0.1/0.2 Ml 96-Well Full-Skirt, Half-Skirt/Non-Skirt PCR Plates
Find Similar Products

Basic Info.

Model NO.
60-0056/1016/0016/0156/0256/0356/0456
Origin
China
HS Code
39172200

Product Description

Laboratory Consumables 0.1/0.2 ml 96-well Full-Skirt/Half-Skirt/Non-Skirt PCR Plates

Feature:

· 0.1/0.2 ml 96-well PCR Plates, non-steriled

· Materila: medical-grade polypropylene

· Volumes: 0.1ml&0.2ml

· Two skirt types: half-skirted and non-skirted

· Ultra-thin wall of uniform thickness-accelerates heat transfer
· Half-skirted plate provides superior rigidity, non-skirted plate easy to be cut, 
full skirted plate has PC material frame to enhance mechanical strength, making it excellent for use with robotic platforms in an automated workflow

· Alphanumeric coding assist in sample organization; convex design around the aperture for leak-proof.

· All products are DNase, RNase, and endotoxin free.

· Working Temperature: stable from -20ºC to 100ºC.

· Compatible with the PCR instrument; withstand centrifugation of 6,000 RCF in a fully supported rotor

· Fits more standard thermocyclers

· Can withstand cenreifugation of up to 6,000 RCF

Laboratory Consumables 0.1/0.2 Ml 96-Well Full-Skirt, Half-Skirt/Non-Skirt PCR Plates
Laboratory Consumables 0.1/0.2 Ml 96-Well Full-Skirt, Half-Skirt/Non-Skirt PCR Plates

Ordering Information
Cat # Volume Well Skirt Color Sterile Unit
60-0056 0.2ml 96-well Half-Skirted Clear No 25/Pack, 100/Case
60-0156 0.2ml 96-well Half-Skirted Pink No 25/Pack, 100/Case
60-0256 0.2ml 96-well Half-Skirted Green No 25/Pack, 100/Case
60-0356 0.2ml 96-well Half-Skirted Blue No 25/Pack, 100/Case
60-0456 0.2ml 96-well Half-Skirted Yellow No 25/Pack, 100/Case
60-0016 0.2ml 96-well Non-Skirted Clear No 10 Plates/Pack,100 Plates/Case
60-1016 0.1ml 96-well Non-Skirted Clear No 10 Plates/Pack,100 Plates/Case
60-0016W 0.2ml 96-well Non-Skirted White No 10 Plates/Pack,100 Plates/Case
60-1016W 0.1ml 96-well Non-Skirted White No 10 Plates/Pack,100 Plates/Case
60-1016F 0.1ml 96-well Full-Skirted White base, clear wells No 10 Plates/Pack, 50 Plates/Case
60-1016F-W 0.1ml 96-well Full-Skirted White base, white wells No 10 Plates/Pack, 50 Plates/Case


Laboratory Consumables 0.1/0.2 Ml 96-Well Full-Skirt, Half-Skirt/Non-Skirt PCR Plates
1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2. What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3. What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier