Laboratory Disposable Consumable 1/10μ L Gamma Radition Steriled Inoculating Needles & Loop

Product Details
After-sales Service: 5 Years
Warranty: 5 Years
Disposable: Disposable
Still deciding? Get samples of US$ 0/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Laboratory Disposable Consumable 1/10μ L Gamma Radition Steriled Inoculating Needles & Loop
  • Laboratory Disposable Consumable 1/10μ L Gamma Radition Steriled Inoculating Needles & Loop
  • Laboratory Disposable Consumable 1/10μ L Gamma Radition Steriled Inoculating Needles & Loop
  • Laboratory Disposable Consumable 1/10μ L Gamma Radition Steriled Inoculating Needles & Loop
  • Laboratory Disposable Consumable 1/10μ L Gamma Radition Steriled Inoculating Needles & Loop
  • Laboratory Disposable Consumable 1/10μ L Gamma Radition Steriled Inoculating Needles & Loop
Find Similar Products

Basic Info.

Model NO.
65-0002/65-0001/65-0010
Certification
CE, ISO, FDA
Size
1μl/10μl
Color
Blue/Orange/Yellow
Sterile
Yes
Non-Pyrogenic
Yes
Unit
25 /Bag, 40 Bags/Case
Total
1000/Case
Transport Package
25 Pieces/Pack, 1, 000 Pieces/Case
Specification
199MM length
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China

Packaging & Delivery

Package Size
10.00cm * 10.00cm * 6.00cm
Package Gross Weight
1.000kg

Product Description

L
aboratory Disposable Consumable 1/10μl Gamma Radition Steriled Inoculating Needles & Loops

Feature:

Sterile PS Individually Wrapped Disposable Inoculating Loops&needles

Advantages
· Biologix sterile disposable inoculating loops and needles are made of medical grade polystyrene
· Biologix individual wrapped disposable inoculating loops available in 1μL and 10μL sizes
· The opposite end of each loop can be used as a needle
· Biologix sterile disposable inoculating needles are suitable for removal of single-colony specimens
· Gamma radiation sterilized, non-pyrogenic
· Biologix PS disposable inoculating loops and needles are packaged in resealable bags


Laboratory Disposable Consumable 1/10μ L Gamma Radition Steriled Inoculating Needles & Loop
Laboratory Disposable Consumable 1/10μ L Gamma Radition Steriled Inoculating Needles & Loop
Ordering Information
Cat # Material Volume Description Color Unit
65-0001 PS 1μl Loops Blue 25 Pieces/Pack, 1,000 Pieces/Case
65-0010 PS 10μl Loops Orange 25 Pieces/Pack, 1,000 Pieces/Case
65-0002 PS - Needles Yellow 25 Pieces/Pack, 1,000 Pieces/Case

 

Laboratory Disposable Consumable 1/10μ L Gamma Radition Steriled Inoculating Needles & Loop1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2.  What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3.  What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier