Laboratory Autoclavable Tri-Corner Design 50ml, 100ml, 250ml, 400ml, 800ml, and 1000ml Beakers

Product Details
Disposable: Disposable
Certification: CE, ISO, FDA
Material: PP
Still deciding? Get samples of US$ 0/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Laboratory Autoclavable Tri-Corner Design 50ml, 100ml, 250ml, 400ml, 800ml, and 1000ml Beakers
  • Laboratory Autoclavable Tri-Corner Design 50ml, 100ml, 250ml, 400ml, 800ml, and 1000ml Beakers
  • Laboratory Autoclavable Tri-Corner Design 50ml, 100ml, 250ml, 400ml, 800ml, and 1000ml Beakers
  • Laboratory Autoclavable Tri-Corner Design 50ml, 100ml, 250ml, 400ml, 800ml, and 1000ml Beakers
  • Laboratory Autoclavable Tri-Corner Design 50ml, 100ml, 250ml, 400ml, 800ml, and 1000ml Beakers
  • Laboratory Autoclavable Tri-Corner Design 50ml, 100ml, 250ml, 400ml, 800ml, and 1000ml Beakers
Find Similar Products

Basic Info.

Model NO.
93-0050 93-0100 93-0250 93-0400 93-0800 93-1000
Autoclavable
Yes
Volume
50ml, 100ml, 250ml, 400ml, 800ml, and 1000ml
Sterile
No
Unit
25 Pieces/Sleeve, 4 Sleeves/Case
Total
100/Case
Design
Tri-Corner
Transport Package
25 Pieces/Sleeve, 4 Sleeves/Case
Specification
50ml, 100ml, 250ml, 400ml, 800ml, and 1000ml
Trademark
BIOLOGIX
Origin
Changzhou, Jiangsu, China.

Product Description

Laboratory Autoclavable Tri-corner 50ml, 100ml, 250ml, 400ml, 800ml, and 1000ml Beakers

Feature:
· Biologix tri-corner design beakers
· Available in 50ml, 100ml, 250ml, 400ml, 800ml, and 1000ml
· Made of strong, medical grade polypropylene, autoclavable
· Tri-corner design provides three dripless pouring spouts
· Six different sizes meet different needs

Laboratory Autoclavable Tri-Corner Design 50ml, 100ml, 250ml, 400ml, 800ml, and 1000ml Beakers

Laboratory Autoclavable Tri-Corner Design 50ml, 100ml, 250ml, 400ml, 800ml, and 1000ml Beakers
Laboratory Autoclavable Tri-Corner Design 50ml, 100ml, 250ml, 400ml, 800ml, and 1000ml Beakers

Ordering Information
Cat # Material Autoclavable Volume Sterile Unit
93-0050 PP Yes 50ml NO 25 Pieces/Sleeve, 4 Sleeves/Case
93-0100 PP Yes 100ml NO 25 Pieces/Sleeve, 4 Sleeves/Case
93-0250 PP Yes 250ml NO 25 Pieces/Sleeve, 4 Sleeves/Case
93-0400 PP Yes 400ml NO 25 Pieces/Sleeve, 4 Sleeves/Case
93-0800 PP Yes 800ml NO 25 Pieces/Sleeve, 4 Sleeves/Case
93-1000 PP Yes 1000ml NO 25 Pieces/Sleeve, 4 Sleeves/Case

 

Laboratory Autoclavable Tri-Corner Design 50ml, 100ml, 250ml, 400ml, 800ml, and 1000ml Beakers1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier