Thermalseal Rts Sealing Films Are Based on 50 µ M Polyolefin Films with 50 µ M Inert Encapsulated Silicone Adhesive

Disposable: Disposable
Certification: CE, ISO, FDA
Reactant State: Solid
Material: Polyolefin
Dnase & Rnase Free: Yes
Application: Used for Qpcr, Storage & Crystallization
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
61-0210 61-0250
Temperature Range
-70 °c to - 100 °c
Transport Package
100 /Case
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China

Product Description

ThermalSeal RTS sealing films are based on 50 µm polyolefin films with 50 µm inert encapsulated silicone adhesive. 
Thermalseal Rts Sealing Films Are Based on 50 µ M Polyolefin Films with 50 µ M Inert Encapsulated Silicone Adhesive
Thermalseal Rts Sealing Films Are Based on 50 µ M Polyolefin Films with 50 µ M Inert Encapsulated Silicone Adhesive
 
Thermalseal Rts Sealing Films Are Based on 50 µ M Polyolefin Films with 50 µ M Inert Encapsulated Silicone Adhesive
Thermalseal Rts Sealing Films Are Based on 50 µ M Polyolefin Films with 50 µ M Inert Encapsulated Silicone Adhesive
 
Characteristic
 

-- 50 µm polyolefin films

-- 50 µm inert encapsulated silicone adhesive

-- Dimensions 78.6 by 139.7 mm

-- Length 113.0 mm

-- Recommended for temperatures from-70 °C to +100 °C

-- Used for qPCR, storage & crystallization

-- High optical clarity

-- Minimal to no autofluorescence

-- Chemically inert; no extractables except at extreme pH

-- DMSO resistant for HTS

-- Heat resistant, recommended for temperatures from

-- Certified DNase-, RNase-, and nucleic-acid-free

-- Fit within raised plate rim to prevent loss of seal due to film lifting

-- Silicone adhesive forms the strongest available seal for evaporation prevention

-- Non-tacky adhesive layer simplifies handling of film prior to sealing

 

    Ordering Information
     
    Cat # Description Quantity

    61-0210 

    ThermalSeal RTS Sealing Films, Non-Sterile 

    100

    61-0250

    ThermalSeal RTS Sealing Films, Sterile 

    50
    Thermalseal Rts Sealing Films Are Based on 50 µ M Polyolefin Films with 50 µ M Inert Encapsulated Silicone Adhesive
    1.What are the main factors that influence the maximum centrifugal acceleration force?
    Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
    The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
    Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
    2.What are autoclaving guidelines of plastics?
    To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
    3.What are Biologix's Commitments to Quality?
    We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 
     

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now

    You Might Also Like

    Product Groups

    Gold Member Since 2021

    Suppliers with verified business licenses

    Manufacturer/Factory
    Type of Ownership
    Limited Company
    Management System Certification
    ISO 9001, GMP