0.5ml Self-Standing Microtubes with CE Certificate and Steril

Product Details
Type: General Lab Supplies
Material: Plastic
Ethylene Oxide Sterilization: Ethylene Oxide Sterilization
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • 0.5ml Self-Standing Microtubes with CE Certificate and Steril
  • 0.5ml Self-Standing Microtubes with CE Certificate and Steril
  • 0.5ml Self-Standing Microtubes with CE Certificate and Steril
  • 0.5ml Self-Standing Microtubes with CE Certificate and Steril
  • 0.5ml Self-Standing Microtubes with CE Certificate and Steril
  • 0.5ml Self-Standing Microtubes with CE Certificate and Steril
Find Similar Products

Basic Info.

Model NO.
81-0054/0056/0153/0203
Quality Guarantee Period
Two Years
Group
Adult
Logo Printing
With Logo Printing
Color
Clear
Steril
Yes
Autocalvable
Offer
Name
Tube
Height
30/31/4.5/45.1
Standing
Option
Transport Package
500 Tubes/Pack, 8 Packs/Case
Specification
CE, FDA, ISO9001
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China
HS Code
3101001100
Production Capacity
200 Cases/Week

Product Description

Features

*Ultimate in applications from sample storage in vapor phase liquid nitrogen toboiling applications

*Polypropylene material makes these screw cap tubes perfect for almost every long term storage application.

*Superior clarity and phenomenal strength

*Universal screw threads for use

*Tubes fit most common rotors

*Autoclavable to 121°C and freezable to -181°C

 

Cat #
 

Volume
 

Bottom
 

Color
 

Sterile
 

Unit
 

81-0053
 

0.5ml
 

Conical
 

Clear
 

No
 

500 Tubes/pack, 8 Packs/case
 

81-0054
 

0.5ml
 

Self-Standing
 

Clear
 

No
 

500 Tubes/pack, 8 Packs/case
 

81-0153
 

1.5ml
 

Conical
 

Clear
 

No
 

500 Tubes/pack, 8 Packs/case
 

81-0154
 

1.5ml
 

Self-Standing
 

Clear
 

No
 

500 Tubes/pack, 8 Packs/case
 

81-0203
 

2.0ml
 

Conical
 

Clear
 

No
 

500 Tubes/pack, 8 Packs/case
 

81-0204
 

2.0ml
 

Self-Standing
 

Clear
 

No
 

500 Tubes/pack, 8 Packs/case
 

81-0000
 

Caps
 

-
 

Clear
 

No
 

500 Caps/pack, 8 Packs/case
 

81-0001
 

Caps
 

-
 

Pink
 

No
 

500 Caps/pack, 8 Packs/case
 

81-0002
 

Caps
 

-
 

Green
 

No
 

500 Caps/pack, 8 Packs/case
 

81-0003
 

Caps
 

-
 

Blue
 

No
 

500 Caps/pack, 8 Packs/case
 

81-0004
 

Caps
 

-
 

Yellow
 

No
 

500 Caps/pack, 8 Packs/case
 

81-0005
 

Caps
 

-
 

Assorted
 

NO
 

500 Caps/pack, 8 Packs/case
 
0.5ml Self-Standing Microtubes with CE Certificate and Steril0.5ml Self-Standing Microtubes with CE Certificate and Steril0.5ml Self-Standing Microtubes with CE Certificate and Steril0.5ml Self-Standing Microtubes with CE Certificate and Steril
  1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
  1. What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier