• Max. Speed 4000rpm. Rotor Speed Can Be Set in Rpm/Rcf, with 3 Programs Storage Capacity for Routine Applications. Clinical Centrifuge.
  • Max. Speed 4000rpm. Rotor Speed Can Be Set in Rpm/Rcf, with 3 Programs Storage Capacity for Routine Applications. Clinical Centrifuge.

Max. Speed 4000rpm. Rotor Speed Can Be Set in Rpm/Rcf, with 3 Programs Storage Capacity for Routine Applications. Clinical Centrifuge.

Warranty: 1 Year
Certification: CE, ISO, FDA
Power Input: Single Phase,100V-240V, 50Hz/60Hz
Type: Clinical Centrifuge
Max. Rcf: 2500/1900g
Speed Accuracy: 100rpm
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
01-860X / 01-870X
Other
Clinical Centrifuge
Transport Package
1/Case
Trademark
Biologix
Origin
Changzhou, Jiangsu, China

Product Description

Clinical Centrifuge
Max. Speed 4000rpm. Rotor Speed Can Be Set in Rpm/Rcf, with 3 Programs Storage Capacity for Routine Applications. Clinical Centrifuge.
Max. Speed 4000rpm. Rotor Speed Can Be Set in Rpm/Rcf, with 3 Programs Storage Capacity for Routine Applications. Clinical Centrifuge.


Features


01-860X

--Max. speed 4000rpm.
--Rotor speed can be set in RPM/RCF, with 3 programs storage capacity for routine applications.
--Max. capacity 50ml×4, Adapt to different sizes of blood collection tubes and centrifuge tubes suitable for swing        out  rotor and angle rotor. Automatic  internal diagnosis and self-detection.
--Maintenance-free brushless DC motor.
--Noise:≤62dB(A)
--Power:Single phase,100V-240V, 50Hz/60Hz.


01-870X
 

--Speed range of 300-4000rpm.
--3 programs storage capacity for routine applications.
--Automatic internal diagnosis. Maintenance free brushless DC motor.
--Noise:≤60dB(A)
--Power:Single phase,100V-240V, 50Hz/60Hz
 
Ordering Information
 

Specifications

01-860X

01-870X

 

Speed range

500-4000rpm 

increment: 100rpm

300-4000rpm

increment: 100rpm

 

Max. RCF

2500×g

1900×g

 

Speed accuracy

±100rpm

±100rpm

 
Rotor

Swing6×15ml

Swing4×50ml

Angle 24×15 ml,

Angle 12×10ml/8×15ml

Angel 8×15ml (Default),

Angel 10ml×12

 

 
Run time

1-99min, HOLD

1-99min, HOLD  

Motor

Brushless DC motor

Brushless DC motor

 

Display

LCD

LED

 

Program

Blood: 3200rpm10min.

Urine: 1800rpm5min.

Faecal: 1300rpm10min.

Blood: 3200rpm, 10min

Urine: 1800rpm,5min

Faecal: 1300rpm, 10min

 

Safety Device

Automatic internal

diagnosis

Automatic internal

diagnosis

 

Acceleration/deceleration

3↑4↓steps

25s↑35s↓

 

Power

Single phase,

100V-240V, 50Hz/60Hz

Single phase,

100V-240V, 50Hz/60Hz

 

Dimension(W×D×H)

364×440×268mm

286×367× 227mm

 

Weight

14.5kg

9.2kg

 

Noise

≤62dB(A)

≤60dB(A)

 

X: 1-US plug 4-Eur plug 5-UK plug


Max. Speed 4000rpm. Rotor Speed Can Be Set in Rpm/Rcf, with 3 Programs Storage Capacity for Routine Applications. Clinical Centrifuge.1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP