Microporous Filter Plate Can Be Used for Protein Purification, Sample Preparation, Sterile Filtration, and Sample Filtration Before Mass Spectrometry Analysis

Product Details
After-sales Service: 5 Years
Warranty: 5 Years
Disposable: Disposable
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
Find Similar Products

Basic Info.

Model NO.
11-
Certification
CE, ISO, FDA
Reactant State
Reagent
Package
2 Sets/Pack
Transport Package
2 Sets/Pack
Specification
2 Sets/Pack
Trademark
Biologix

Product Description

Microporous Filter Plate

Microporous Filter Plate Can Be Used for Protein Purification, Sample Preparation, Sterile Filtration, and Sample Filtration Before Mass Spectrometry Analysis
Microporous filter plates can be used for protein purification, sample preparation, sterile filtration, and sample filtration before mass spectrometry analysis. The product range is complete, with multiple materials of membranes and pore sizes to choose from. Each type has been carefully designed to ensure excellent filtering performance in different application scenarios.

 

Microporous Filter Plate Can Be Used for Protein Purification, Sample Preparation, Sterile Filtration, and Sample Filtration Before Mass Spectrometry Analysis
Ordering Information
 
Cat #
Description
Qty
11-MCE24722
24-Well Filter Plate, 7mL, 0.22μm, MCE, supporting collection board
2 Sets/Pack
11-MCEL24722S
24-Well Filter Plate, 7mL, 0.22μm, Hydrophilic MCE, supporting collection board, Sterile
2 Sets/Pack
11-MCE24745
24-Well Filter Plate, 7mL, 0.45μm, MCE, supporting collection board
2 Sets/Pack
11-NYL24722
24-Well Filter Plate, 7mL, 0.22μm, Hydrophilic Nylon, supporting collection board
2 Sets/Pack
11-NYL24722S
24-Well Filter Plate, 7mL, 0.22μm, Hydrophilic Nylon, supporting collection board, Sterile
2 Sets/Pack
11-PESL24722
24-Well Filter Plate, 7mL, 0.22μm, Hydrophilic PES, supporting collection board
2 Sets/Pack
11-PTFEL24722S
24-Well Filter Plate, 7mL, 0.22μm, Hydrophilic PTFE, supporting collection board, Sterile
2 Sets/Pack
11-PVDFB24722
24-Well Filter Plate, 7mL, 0.22μm, Hydrophobic PVDF, supporting collection board
2 Sets/Pack
11-PVDFB24745
24-Well Filter Plate, 7mL, 0.45μm, Hydrophobic PVDF, supporting collection board
2 Sets/Pack
11-CAL960345
96-Well Filter Plate, 300μL, 0.45μm, Hydrophilic CA
10 Pcs/Pack
11-MCEL960322
96-Well Filter Plate, 300μL, 0.22μm, Hydrophilic MCE
10 Pcs/Pack
11-MCEL960322S
96-Well Filter Plate, 300μL, 0.22μm, Hydrophilic MCE, Sterile
10 Pcs/Pack
11-MCEL960345
96-Well Filter Plate, 300μL, 0.45μm, Hydrophilic MCE
10 Pcs/Pack
11-NYL960322
96-Well Filter Plate, 300μL, 0.22μm, Hydrophilic Nylon
10 Pcs/Pack
11-PESL960322
96-Well Filter Plate, 300μL, 0.22μm, Hydrophilic PES
10 Pcs/Pack
11-PTFEB960322
96-Well Filter Plate, 300μL, 0.22μm, Hydrophobic PTFE
10 Pcs/Pack
11-PTFEB960345
96-Well Filter Plate, 300μL, 0.45μm, Hydrophobic PTFE
10 Pcs/Pack
11-PTFEL960322
96-Well Filter Plate, 300μL, 0.22μm, Hydrophilic PTFE
10 Pcs/Pack
11-PTFEL960345
96-Well Filter Plate, 300μL, 0.45μmHydrophilic PTFE
10 Pcs/Pack
11-PVDFB960322
96-Well Filter Plate, 300μL, 0.22μm, Hydrophobic PVDF
10 Pcs/Pack
11-PVDFB960345
96-Well Filter Plate, 300μL, 0.45μmHydrophobic PVDF
10 Pcs/Pack
11-PVDFL960322
96-Well Filter Plate, 300μL, 0.22μm, Hydrophilic PVDF
10 Pcs/Pack
11-PVDFL960345
96-Well Filter Plate, 300μL, 0.45μm, Hydrophilic PVDF
10 Pcs/Pack
11-CAL9622NS
Non-removable 96-Well Filter Plate, 0.22μm, Hydrophilic CA, Sterile
10 Pcs/Pack
11-CAL9645N
Non-removable 96-Well Filter Plate, 0.45μm, Hydrophilic CA
10 Pcs/Pack
11-NYL9622N
Non-removable 96-Well Filter Plate, 0.22μm, Hydrophilic Nylon
10 Pcs/Pack
11-NYL9645N
Non-removable 96-Well Filter Plate, 0.45μm, Hydrophilic Nylon
10 Pcs/Pack
11-PVDFL9622NS
Non-removable 96-Well Filter Plate, 0.22μm, Hydrophilic PVDF, Sterile
10 Pcs/Pack


Microporous Filter Plate Can Be Used for Protein Purification, Sample Preparation, Sterile Filtration, and Sample Filtration Before Mass Spectrometry Analysis
What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now