• 90X15mm Sterile Clear Petri Dish for Laboratory
  • 90X15mm Sterile Clear Petri Dish for Laboratory
  • 90X15mm Sterile Clear Petri Dish for Laboratory

90X15mm Sterile Clear Petri Dish for Laboratory

Disposable: Disposable
Certification: CE, ISO
Material: Plastic
Color: Clear
Type: Culture Dish
Size (mm): 90X15
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
66-1501
Transport Package
10 /Bag, 50 Bags/Case
Specification
CE, ISO, FDA
Trademark
BIOLOGIX
Origin
Changzhou, Jiangsu
HS Code
3926909090
Production Capacity
500 Cases/Month

Product Description

90X15mm Sterile Clear Petri Dish For Laboratory

 
90X15mm Sterile Clear Petri Dish for Laboratory
90X15mm Sterile Clear Petri Dish for Laboratory
90X15mm Sterile Clear Petri Dish for Laboratory


1. Features

1. Made of medical grade polystyrene
2. Highly transparent for microscopic analysis
3. Three sizes available: 60mm, 90mm, or 150mm in diameter
4. Vented lid for better gas exchange
5. Dishes are stackable
6. EO Sterile

2.Ordering Information
 
Cat # Size (mm) Color Sterile Unit

66-1501

90x15

Clear Yes 10 Pieces/Bag, 50 Bags/Case
 

90X15mm Sterile Clear Petri Dish for Laboratory90X15mm Sterile Clear Petri Dish for Laboratory90X15mm Sterile Clear Petri Dish for Laboratory90X15mm Sterile Clear Petri Dish for Laboratory
    1. What are the main factors that influence the maximum centrifugal acceleration force?
    Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
    The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
    Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
    2. What are autoclaving guidelines of plastics?
    To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
    3. What are Biologix's Commitments to Quality?

    We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

     

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now

    You Might Also Like

    Gold Member Since 2021

    Suppliers with verified business licenses

    Manufacturer/Factory
    Type of Ownership
    Limited Company
    Management System Certification
    ISO 9001, GMP