Qpcr 8 Strip PCR Tube Dnase Rnase Real Time PCR

Product Details
Disposable: Disposable
Certification: CE, ISO
Reactant State: Liquid
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Qpcr 8 Strip PCR Tube Dnase Rnase Real Time PCR
  • Qpcr 8 Strip PCR Tube Dnase Rnase Real Time PCR
  • Qpcr 8 Strip PCR Tube Dnase Rnase Real Time PCR
  • Qpcr 8 Strip PCR Tube Dnase Rnase Real Time PCR
  • Qpcr 8 Strip PCR Tube Dnase Rnase Real Time PCR
  • Qpcr 8 Strip PCR Tube Dnase Rnase Real Time PCR
Find Similar Products

Basic Info.

Material
PP Material
Cap
Flat Top / Dome-Shaped
Tube
8-Strip
Qpcr
Flat Caps Are Ideal for Real-Time PCR (Qpcr)
Character
Faster Heating and Cooling
Dnase Rnase Free
Dnase Rnase and Endotoxin Free
Transport Package
125 Strip Tubes+125 Strip Caps/Bag/Pack, 10 Packs
Specification
0.2ml
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China

Product Description


 

Qpcr 8 Strip PCR Tube Dnase Rnase Real Time PCR
Qpcr 8 Strip PCR Tube Dnase Rnase Real Time PCR


Features

Made of high quality medical grade polypropylene
Ultra thin-wall tubes provide faster heating and cooling
High degree of transparency allows for easy observation of samples
Available with domed caps or flat caps
Domed caps ensure efficient heat transfer
Flat caps are ideal for Real-Time PCR (qPCR)
Unique cap design prevents opening during cycling and incubation stage
DNase, RNase, and endotoxin free

Ordering Information
 
Cat# Volume Color Cap Sterile Unit
60-0088 0.2ml Clear Flat-top NO 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case

60-0188

0.2ml Pink Flat-top NO 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case

60-0288

0.2ml Green Flat-top NO 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case

60-0388

0.2ml Blue Flat-top NO 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case

60-0488

0.2ml Yellow Flat-top NO 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case
60-0008 0.2ml Clear Dome-shaped NO 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case
60-0108 0.2ml Pink Dome-shaped NO 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case
60-0208 0.2ml Green Dome-shaped NO 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case
60-0308 0.2ml Blue Dome-shaped NO 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case
60-0408 0.2ml Yellow Dome-shaped NO 125 Strip Tubes+125 Strip Caps/Pack, 10 Packs/Case


Qpcr 8 Strip PCR Tube Dnase Rnase Real Time PCRQpcr 8 Strip PCR Tube Dnase Rnase Real Time PCRQpcr 8 Strip PCR Tube Dnase Rnase Real Time PCRQpcr 8 Strip PCR Tube Dnase Rnase Real Time PCR
1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier