81 mm wide x 100 meters 79 mm wide x 65 meters Adhesive Sealing Films in Roll-Seal Format for Automation
Features:
- Fast, efficient, high-throughput sealing; 2.5-5 seconds/plate; no handling and backing removal from individual sheets
- Hands-free; reduces chance of mishap or contamination; more uniform sealing from plate-to-plate heat-free; no high temperatures to damage sensitive samples or warp plates and cause robotic handling problems
- Especially convenient when working with foils; avoids curling that occurs with individual sheets
- Economical; lower cost per plate than individual sheet seals or heat-seal films
- Easier peel for removal compared to many heat-seal films
- High-precision dispensing with automated sealers; consistent positioning on plates
- Compatible with most current adhesive SBS plate sealers
- Static-free manufacturing and packaging facilitates alignment and adhesion
- Protective packaging prevents damage during shipping
- Plastic cores eliminate corrugate fiber dust
Ordering Information:
Cat # |
Description |
Quantity |
61-0130 |
AeraSeal Film, 81 mm wide x 100 meters long, Non-Sterile |
1 Roll |
61-0131 |
AlumaSeal Foil, 80 mm wide x 100 meters long, Non-Sterile |
1 Roll |
61-0132 |
ThermalSeal RTS Film, 79 mm wide x 65 meters long, Non-Sterile |
1 Roll |
1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2. What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3. What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin,