Disposable: | Disposable |
---|---|
Certification: | CE, ISO |
Reactant State: | Liquid |
Still deciding? Get samples of US$ 0/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
* Single Use and Gamma Ray pre-sterilized.
* Sterile graded 0.2um membrane: LRV>7 for Brevundimonas diminuta, ATCC19146.
* Non-pyrogenic, low extractables and surfactant-free ensures purity of filtrate.
* Extreme-low Protein Binding <1.5% (PES).
* Excellent Thoughput, for faster filtration and more process volume.
Applications:
1. Sterile filtration and clarification of biological fluids.
2. Tissue culture media preparation.
3. Protein and enzyme filtration.
4. Hybridization buffers.
5. Other aqueous solution.
CAT# | DECRIPTION | TO REPLACE | Pack Size |
08-PES1322R |
Membrane: PES, pore size: 0.22μm, diameter:13mm. Female luer lock + male luer slip. Extreme-low protein binding. Individually packed. |
Millipore SLGV013SL Whatman 6780-1302/6791-1302 Pall 4602 |
100 Pcs/Pack, 8 Packs/Case, Case of 800 |
08-PES2522R |
Membrane: PES, pore size: 0.22μm, diameter:25mm. Female luer lock + male luer slip. Extreme-low protein binding. Individually packed. |
Millipore SLMP025SS/SLMP025SS Whatman 6780-2502/6780-2512/ 9913-2502 Pall 4612/4902/4907/4520 |
100 Pcs/Pack, 4 Packs/Case, Case of 400 |
08-PES3022R |
Membrane: PES, pore size: 0.22μm, diameter:30mm. Female luer lock + male luer slip. Extreme-low protein binding. Individually packed. |
Millipore SLMP025SS/SLMP025SS Whatman 6780-2502/6780-2512 Pall 4612/4902 |
100 Pcs/Pack, 4 Packs/Case, Case of 400 |
08-PES3322S |
Membrane: PES, pore size: 0.22μm, diameter:33mm. Double luer lock. Extreme-low protein binding. Individually packed. |
Sartorius16532----GUK Sartorius16532------K Sartorius16532----------Q Sartorius 16534---------K |
100 Pcs/Pack, 4 Packs/Case, Case of 400 |
08-PES3345S |
Membrane: PES, pore size: 0.45μm, diameter:33mm. Double luer lock. Extreme-low protein binding. Individually packed. |
Sartorius16537-----K Sartorius16537-----Q Sartorius 16555----K |
100 Pcs/Pack, 4 Packs/Case, Case of 400 |
08-PES3322M |
Membrane: PES, pore size: 0.22μm, diameter:33mm. Female luer lock + male luer slip. High pressure resistance. Individually packed. |
Millipore SLGP033RB/SLGP033RK/ SLGP033 RS/SLGV033RS/ SLGV033RB/SLGV033RK Sartorius 16541----K/16541----Q Pall 4652 Whatman1046-2200/1046-2205 |
100 Pcs/Pack, 4 Packs/Case, Case of 400 |
08-PES3345M |
Membrane: PES, pore size: 0.45μm, diameter:33mm. Female luer lock + male luer slip. High pressure resistance. Individually packed. |
Millipore SLHP033RB/SLHP033RS/ SLHV033 RS/ SLHV033RB/ SLHV033RK Sartorius16533----K/16533----Q Pall 4654/4406 Whatman 1046-2100 |
100 Pcs/Pack, 4 Packs/Case, Case of 400 |
08-CA3022R |
Membrane: CA, pore size: 0.22μm, diameter:30mm. Female luer lock + male luer slip. High biocompatibility. Individually packed. |
Sartorius 17597----K Whatman 1046-2200 Whatman 1046-2205 |
100 Pcs/Pack, 4 Packs/Case, Case of 400 |
08-CA3045R |
Membrane: CA, pore size: 0.45μm, diameter:30mm. Female luer lock + male luer slip. High biocompatibility. Individually packed. |
Whatman 1046-2100 |
100 Pcs/Pack, 4 Packs/Case, Case of 400 |
09-PES2250 |
Vacuum filtration unit, membrane: PES, pore size: 0.22μm, diameter:90mm, funnel volume: 500ml, receiver volume: 500ml. |
Thermo 566-0020 Corning 431097 Millipore S2GPU05RE Millipore S2GVU05RE Sartorius 180C2----------E |
12 |
09-PES2250F |
Vacuum filtration unit-funnel, membrane: PES, pore size: 0.22μm, diameter:90mm, funnel volume: 500ml. |
Millipore SCGPT05RE/ S2GPT10RE /SCGPT10RE Sartorius 180C5----------E/ 180C6----------E Thermo 595-4520/ 597-4520 Corning 431118/ 431174 |
24 |
09-CA2250 |
Vacuum filtration unit-funnel, membrane: CA, pore size: 0.22μm, diameter:90mm, funnel volume: 500ml, receiver volume: 500ml. |
Thermo 156-4020/156-0020 Corning 430769 |
12 |
09-CA2250F |
Vacuum filtration unit-funnel, membrane: CA, pore size: 0.22μm, diameter:90mm, funnel volume: 500ml. |
Thermo 291-4520/292-4520 Corning 430513/430514/430515 |
24 |
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc.