Lab Disposable Tc-Treated Clear Transparent Sterile 6/12/24/48/96 Well Cell Culture Plates Factory Price

Product Details
Certification: CE, ISO
Material: Rubber / Plastic
Wells: 6/12/24/48/96-Well
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Lab Disposable Tc-Treated Clear Transparent Sterile 6/12/24/48/96 Well Cell Culture Plates Factory Price
  • Lab Disposable Tc-Treated Clear Transparent Sterile 6/12/24/48/96 Well Cell Culture Plates Factory Price
  • Lab Disposable Tc-Treated Clear Transparent Sterile 6/12/24/48/96 Well Cell Culture Plates Factory Price
  • Lab Disposable Tc-Treated Clear Transparent Sterile 6/12/24/48/96 Well Cell Culture Plates Factory Price
  • Lab Disposable Tc-Treated Clear Transparent Sterile 6/12/24/48/96 Well Cell Culture Plates Factory Price
  • Lab Disposable Tc-Treated Clear Transparent Sterile 6/12/24/48/96 Well Cell Culture Plates Factory Price
Find Similar Products

Basic Info.

Model NO.
07-6006
Working Volume
3/2/21/0.5/0.2ml
Sterile
Yes
Tc Treated
Yes
Sterilization Method
Gamma Radiation Sterilized
Unit
1 Piece/Pack, 50 Packs/Case
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China
HS Code
3926909090
Production Capacity
200 Cases/Week

Product Description

Lab Disposable TC-Treated Clear Transparent Sterile 6/12/24/48/96 Well Cell Culture Plates Factory Price

Feature:

· 6/12/24/48/96 well Cell Culture Plates Lab Disposable TC-treated Clear

· Material: PS
· Plate cover design minimizes the risk of cross contamination
· Thin-walled well bottoms increase thermal consistency, reducing the edge effect
· Flat well bottoms provide excellent clarity for microscopic examination of samples
· Raised well rim design around each well enables secure sealing and safeguards against evaporation
· Radiation sterilization
· Non-pyrogenic, non-cytotoxic
· DNase & RNase free, human DNA free
· TC treated

 

Application

Cell culture plates are widely used in the fields of life science, molecular biology, immunology, biochemistry, genetics and so on. For example, in gene editing experiments, cell culture plates can provide a culture environment suitable for gene editing systems, so as to achieve operations such as DNA editing, transfection and gene expression.

 

Lab Disposable Tc-Treated Clear Transparent Sterile 6/12/24/48/96 Well Cell Culture Plates Factory Price
Lab Disposable Tc-Treated Clear Transparent Sterile 6/12/24/48/96 Well Cell Culture Plates Factory Price
Lab Disposable Tc-Treated Clear Transparent Sterile 6/12/24/48/96 Well Cell Culture Plates Factory Price
Ordering Information
Cat # Material Wells

External Dimensions

W x Lx H (mm)

Working Volume(mL) TC Treated Unit
07-6006 PS 6 85.4x127.6x20.2 3 Yes 1 Pcs/Pack, 50 Packs/Case
07-6012 PS 12 85.4x127.6x20.2 2 Yes 1 Pcs/Pack, 50 Packs/Case
07-6024 PS 24 85.4x127.6x20.2 1 Yes 1 Pcs/Pack, 50 Packs/Case
07-6048 PS 48 85.4x127.6x20.2 0.5 Yes 1 Pcs/Pack, 50 Packs/Case
07-6096 PS 96 85.4x127.6x14.4 0.2 Yes 1 Pcs/Pack, 50 Packs/Case

Lab Disposable Tc-Treated Clear Transparent Sterile 6/12/24/48/96 Well Cell Culture Plates Factory Price1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2. What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3. What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier