Laboratory Consumable Disposable Plastic PP Sterile 15/50ml Flat Top/Plug Seal Conical Bottom Centrifuge Tubes

Product Details
Certification: CE, ISO, FDA
Material: Glass
Capacity: 15/50ml
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Laboratory Consumable Disposable Plastic PP Sterile 15/50ml Flat Top/Plug Seal Conical Bottom Centrifuge Tubes
  • Laboratory Consumable Disposable Plastic PP Sterile 15/50ml Flat Top/Plug Seal Conical Bottom Centrifuge Tubes
  • Laboratory Consumable Disposable Plastic PP Sterile 15/50ml Flat Top/Plug Seal Conical Bottom Centrifuge Tubes
  • Laboratory Consumable Disposable Plastic PP Sterile 15/50ml Flat Top/Plug Seal Conical Bottom Centrifuge Tubes
  • Laboratory Consumable Disposable Plastic PP Sterile 15/50ml Flat Top/Plug Seal Conical Bottom Centrifuge Tubes
  • Laboratory Consumable Disposable Plastic PP Sterile 15/50ml Flat Top/Plug Seal Conical Bottom Centrifuge Tubes
Find Similar Products

Basic Info.

Model NO.
10-9151/10-9152/10-9501/10-9815
Volume(Ml)
15/50ml
Caps
Flat Top/Plug Seal
Package
Rack/Bulk
Bottom
Conical Bottom
Rnase and Dnase Free
Yes
Unit
50 Sets/Rack, 10 Racks/Case
Transport Package
500 /Case
Specification
50 /Rack, 10 Racks /Case
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China

Product Description

Laboratory Consumable Disposable PP Sterile 15/50ml Flat Top/Plug Seal Conical Bottom Centrifuge Tubes

Feature:

· 50ml High Quality Flat Cap Conical Bottom PP Centrifuge Tube 

· Tubes: polypropylene

· Flat-top caps: polyethylene

· Plug-seal screw on caps: polypropylene

· Volume: 15ml and 50ml; with large white writing area

· Double threaded design reduces cross-threading; caps are easily opened and closed

· Gamma radiation sterilized, non-pyrogenic

· Available in racked package (sterile) or bulk package (sterile & non-sterile)

· RNase & DNase free

· Working temperature: stable from -20°C to 121°C (except flat-top cap)

· 50ml High Quality Flat Cap Conical Bottom PP Centrifuge Tube


Laboratory Consumable Disposable Plastic PP Sterile 15/50ml Flat Top/Plug Seal Conical Bottom Centrifuge Tubes
Laboratory Consumable Disposable Plastic PP Sterile 15/50ml Flat Top/Plug Seal Conical Bottom Centrifuge Tubes
Ordering Infromation
Cat # Material Volume Centrifugal force Caps Sterile Package Unit
10-9151 PP 15 8400G Flat Top Yes Rack 50/Rack, 10 Racks/Case
10-9152 PP 15 8400G Flat Top Yes Bulk 25/Pack, 20 Packs/Case
10-9501 PP 50 9400 G Flat Top Yes Rack 25/Pack, 20 Packs/Case
10-9502 PP 50 9400 G Flat Top Yes Bulk 25/Pack, 20 Packs/Case
10-9815 PP 15 8400G Flat Top No Bulk 500/Case
10-9850 PP 50 9400 G Flat Top No Bulk 500/Case
10-0151 PP 15 8400G Plug Seal Yes Rack 50/Rack, 10 Racks/Case
10-0152 PP 15 8400G Plug Seal Yes Bulk 25/Pack, 20 Packs/Case
10-0501 PP 50 9400 G Plug Seal Yes Rack 25/Pack, 20 Packs/Case
10-0502 PP 50 9400 G Plug Seal Yes Bulk 25/Pack, 20 Packs/Case
10-0815 PP 15 8400G Plug Seal No Bulk 500/Case
10-0850 PP 50 9400 G Plug Seal No Bulk 500/Case

 

Laboratory Consumable Disposable Plastic PP Sterile 15/50ml Flat Top/Plug Seal Conical Bottom Centrifuge Tubes1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier