Certification: CE, ISO, FDA
Material: Rubber / Plastic
Transport Package: 25 Pieces/Pack, 1, 000 Pieces/Case
Specification: 1ul 10ul
Trademark: BIOLOGIX
Origin: China
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
65-0001 65-0010
HS Code
3926909090

Product Description

1UL 10UL Biologix Inoculation Loops Sterile Lab Disposable Plastic Sterilizer For Laboratory Use

1UL 10UL Biologix Inoculation Loops Sterile Lab Disposable Plastic Sterilizer for Laboratory Use
I. APPLICATIONS
1. Microbiology
2. Cell colony isolation and removal

II. FEATURES
1. Materials: polystyrene
2. Gamma radiation sterilized
3. Disposable
4. Evan's Blue Dye Method Certification included

III. LOOP/NEEDLE DESIGN
1. Loops available in 1μl and 10μl sizes
2. Needles are ideal for the removal of single colonies
3. Ultra-smooth loop surface
4. Needles and Loops are packed in a zip-seal bag

IV. PACKAGING
1. Bulk, 25 pieces per zip-seal bag, 1,000 pieces/case

V. DESCRIPTION
Cat # Volume Description Color Sterile Unit
65-0001 1μl Loops Blue Yes 25 Pieces/Pack, 1,000 Pieces/Case

65-0010

10μl

Loops Orange Yes 25 Pieces/Pack, 1,000 Pieces/Case
65-0002 - Needles Yellow Yes 25 Pieces/Pack, 1,000 Pieces/Case


VI. STERILITY
1. Products are Gamma Radiation Sterilized according to ISO13485 standard.
2. For each lot, sterilization records are recorded and signed off by qualified personnel for product release.

VII. CERTIFICATION
Biologix products are manufactured completely according to the TUV ISO 9001:2008 standard.

VIII. RESTRICTIONS
Refer to the Chemical Resistance Chart in our catalog, and available within our online catalog.


1UL 10UL Biologix Inoculation Loops Sterile Lab Disposable Plastic Sterilizer for Laboratory Use1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2.  What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3.  What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP