10UL PP Material Laboratory Disposable Low Retention Sterile Filter Tips Bulk Or Racked Tips Rnase Dnase Free

Product Details
Disposable: Disposable
Certification: CE, ISO
Certifications: CE ISO FDA
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • 10UL PP Material Laboratory Disposable Low Retention Sterile Filter Tips Bulk Or Racked Tips Rnase Dnase Free
  • 10UL PP Material Laboratory Disposable Low Retention Sterile Filter Tips Bulk Or Racked Tips Rnase Dnase Free
  • 10UL PP Material Laboratory Disposable Low Retention Sterile Filter Tips Bulk Or Racked Tips Rnase Dnase Free
  • 10UL PP Material Laboratory Disposable Low Retention Sterile Filter Tips Bulk Or Racked Tips Rnase Dnase Free
  • 10UL PP Material Laboratory Disposable Low Retention Sterile Filter Tips Bulk Or Racked Tips Rnase Dnase Free
  • 10UL PP Material Laboratory Disposable Low Retention Sterile Filter Tips Bulk Or Racked Tips Rnase Dnase Free
Find Similar Products

Basic Info.

Model NO.
23-0011S
Volume
10UL 20UL 50UL 100UL 200UL 1000UL Pipet Tips
Sterile
Sterile
Rack
96 Tips Per Rack
Dnase & Rnase Free
Dnase & Rnase Free
Low Retention
Optional
Universal
Universal
Transport Package
96 Pieces/Rack, 50 Racks/Case
Specification
10ul
Trademark
Biologix Brand
Origin
Changzhou, Jiangsu
HS Code
3926909090
Production Capacity
1000000 Cases/Month

Product Description

10ul PP Material Laboratory Disposable Low Retention Sterile Filter Tips Bulk or Racked Tips Rnase Dnase Free
10UL PP Material Laboratory Disposable Low Retention Sterile Filter Tips Bulk Or Racked Tips Rnase Dnase Free
10UL PP Material Laboratory Disposable Low Retention Sterile Filter Tips Bulk Or Racked Tips Rnase Dnase Free
10UL PP Material Laboratory Disposable Low Retention Sterile Filter Tips Bulk Or Racked Tips Rnase Dnase Free
10UL PP Material Laboratory Disposable Low Retention Sterile Filter Tips Bulk Or Racked Tips Rnase Dnase Free
 
10UL PP Material Laboratory Disposable Low Retention Sterile Filter Tips Bulk Or Racked Tips Rnase Dnase Free
10UL PP Material Laboratory Disposable Low Retention Sterile Filter Tips Bulk Or Racked Tips Rnase Dnase Free


 
Characteristic

1. Made in Bioclean room.
2. Extremely straight low retention tips ensure accurate and precise sample.
3. Extra-long tips: 10μl with max volume 20μl, 200μl with max volume 300μl, and 1000μl with max volume 1250μl.
4. Racked filter tips, sterile.
5.DNase & RNase free, non-pyrogen.

6. User-friendly label on the tip rack.

7. Materials: Tips are made of PP, filters are made of UHMWPE with pore size 0.22um.

8. Tips all are natural clear color

 


Order Information 

Cat. No.

Description

23-0011S

0.1µl-10µl Filter Tips, rack pack, sterile. Extra-long, low-retention. 96 Pieces/Rack, 50 Racks/Case

23-0021S

1µl-20µl Filter Tips, rack pack, sterile. Extra-long, low-retention. 96 Pieces/Rack, 50 Racks/Case

23-0051S

1µl-50µl Filter Tips, rack pack, sterile. Extra-long, low-retention. 96 Pieces/Rack, 50 Racks/Case

23-0101S

1µl-100µl Filter Tips, rack pack, sterile. Extra-long, low-retention. 96 Pieces/Rack, 50 Racks/Case

23-0201S

1µl-200µl Filter Tips, rack pack, sterile. Extra-long, low-retention. 96 Pieces/Rack, 50 Racks/Case

23-1001S

100µl-1000µl Filter Tips, rack pack, sterile. Extra-long, low-retention. 96 Pieces/Rack, 50 Racks/Case

 

10UL PP Material Laboratory Disposable Low Retention Sterile Filter Tips Bulk Or Racked Tips Rnase Dnase Free
1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier