Sterile. Rnase & Dnase Free. 10µ L, 200µ L and 1000&Micro: L Tip Filter Tips< H Series>

Product Details
Certification: CE, ISO, FDA
Material: PP, UHMWPE
Volume: 10UL, 200UL, 1000UL
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Sterile. Rnase & Dnase Free. 10µ L, 200µ L and 1000&Micro: L Tip Filter Tips< H Series>
  • Sterile. Rnase & Dnase Free. 10µ L, 200µ L and 1000&Micro: L Tip Filter Tips< H Series>
  • Sterile. Rnase & Dnase Free. 10µ L, 200µ L and 1000&Micro: L Tip Filter Tips< H Series>
  • Sterile. Rnase & Dnase Free. 10µ L, 200µ L and 1000&Micro: L Tip Filter Tips< H Series>
  • Sterile. Rnase & Dnase Free. 10µ L, 200µ L and 1000&Micro: L Tip Filter Tips< H Series>
  • Sterile. Rnase & Dnase Free. 10µ L, 200µ L and 1000&Micro: L Tip Filter Tips< H Series>
Find Similar Products

Basic Info.

Sterile
Yes
Character
Rnase, Dnase Free
Other
Filter Tips
Transport Package
96 Pieces/Rack, 50 Racks/Case
Trademark
Biologix
Origin
Changzhou, Jiangsu, China

Product Description

Sterile. RNase & DNase free. 10&micro;l, 200&micro;l and 1000&micro:l tip Filter Tips<H series>
Sterile. Rnase &amp; Dnase Free. 10&micro; L, 200&micro; L and 1000&Micro: L Tip Filter Tips&lt; H Series&gt;
Sterile. Rnase &amp; Dnase Free. 10&micro; L, 200&micro; L and 1000&Micro: L Tip Filter Tips&lt; H Series&gt;
Sterile. Rnase &amp; Dnase Free. 10&micro; L, 200&micro; L and 1000&Micro: L Tip Filter Tips&lt; H Series&gt;
 
Sterile. Rnase &amp; Dnase Free. 10&micro; L, 200&micro; L and 1000&Micro: L Tip Filter Tips&lt; H Series&gt;
Sterile. Rnase &amp; Dnase Free. 10&micro; L, 200&micro; L and 1000&Micro: L Tip Filter Tips&lt; H Series&gt;
Sterile. Rnase &amp; Dnase Free. 10&micro; L, 200&micro; L and 1000&Micro: L Tip Filter Tips&lt; H Series&gt;

Character:

--Tips are made of PP, filters are made of UHMWPE with pore size 0.22um.   

--Tips all are natural clear color
--10µl, 200µl and 1000µl tip sizes available.
--Filters prevent cross-contamination and damage to samples, ensure accurate and precise sample.
--Sterile.
--RNase & DNase free.

 

Ordering Information
 

Cat. No.

Description

23-0010H

10µl, rack pack. Extra-long, 96 Pieces/Rack, 50 Racks/Case

23-0011H

10µl, rack pack, Extra-long, low-retention, 96 Pieces/Rack, 50 Racks/Case

23-0200H

200µl, extra-long,rack pack. 96 Pieces/Rack, 50 Racks/Case

23-0201H

200µl, extra-long,rack pack, low-retention, 96 Pieces/Rack, 50 Racks/Case

23-1000H

1000µl, rack pack, 96 Pieces/Rack, 50 Racks/Case

23-1250H

1000µl, extra-long, rack pack, 96 Pieces/Rack, 50 Racks/Case

23-1251H

1000µl, extra-long, rack pack, low retention, 96 Pieces/Rack, 50 Racks/Case


Sterile. Rnase &amp; Dnase Free. 10&micro; L, 200&micro; L and 1000&Micro: L Tip Filter Tips&lt; H Series&gt;1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier