• Laboratory Disposable PP 5.0ml Self-Standing External Thread Sided-Coded Cryogenic Vials
  • Laboratory Disposable PP 5.0ml Self-Standing External Thread Sided-Coded Cryogenic Vials
  • Laboratory Disposable PP 5.0ml Self-Standing External Thread Sided-Coded Cryogenic Vials
  • Laboratory Disposable PP 5.0ml Self-Standing External Thread Sided-Coded Cryogenic Vials
  • Laboratory Disposable PP 5.0ml Self-Standing External Thread Sided-Coded Cryogenic Vials

Laboratory Disposable PP 5.0ml Self-Standing External Thread Sided-Coded Cryogenic Vials

Certification: CE, ISO, FDA
Material: Rubber / Plastic
Certifications: CE ISO FDA
Volume: 10UL 200UL 100UL Pipet Tips
Sterile: Sterile
Rack: 96 Tips or 100 Tips Per Rack
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
88-650X
Dnase & Rnase Free
Dnase & Rnase Free
Non-Pyrogen
Non-Pyrogen
Low Retention
Optional
Universal
Universal
Specification
10UL 200UL 100UL
Trademark
Biologix Brand
Origin
Changzhou, Jiangsu
Production Capacity
1000000 Cases/Month

Product Description

Laboratory Disposable PP 5.0ml Self-Standing External Thread Sided-Coded Cryogenic Vials 
Feature:

· 5.0 ML Cryogenic Vials With Side Bardcode

· Made of medical grade polypropylene; Autoclavable; and can be repeatedly frozen and thawed

· Colors: Vials with caps which are available in 7 colors

· Bottom: Self-standing

· Working temperature: stable from -196°C to 121°C

· Suitable for liquid nitrogen freezing(vapor phase)

· Fit standard 1in, 2in, and 3.75in cryogenic boxes

· Tubes with black graduation mark and white writing area

· Pre-set 1D barcode and numbers on sides for immediate scanning
 

Laboratory Disposable PP 5.0ml Self-Standing External Thread Sided-Coded Cryogenic Vials
Laboratory Disposable PP 5.0ml Self-Standing External Thread Sided-Coded Cryogenic Vials
Order Information
Cat # Volume Thread Type Color Unit Total
88-6500 5.0ml External Thread White 25 Sets/Bag, 20 Bags/Pack, 2 Packs/Case 1000 Sets/Case
88-6501 5.0ml External Thread Red 25 Sets/Bag, 20 Bags/Pack, 2 Packs/Case 1000 Sets/Case
88-6502 5.0ml External Thread Green 25 Sets/Bag, 20 Bags/Pack, 2 Packs/Case 1000 Sets/Case
88-6503 5.0ml External Thread Blue 25 Sets/Bag, 20 Bags/Pack, 2 Packs/Case 1000 Sets/Case
88-6504 5.0ml External Thread Yellow 25 Sets/Bag, 20 Bags/Pack, 2 Packs/Case 1000 Sets/Case
88-6505 5.0ml External Thread Purple 25 Sets/Bag, 20 Bags/Pack, 2 Packs/Case 1000 Sets/Case
88-6507 5.0ml External Thread Clear 25 Sets/Bag, 20 Bags/Pack, 2 Packs/Case 1000 Sets/Case

Laboratory Disposable PP 5.0ml Self-Standing External Thread Sided-Coded Cryogenic Vials
Laboratory Disposable PP 5.0ml Self-Standing External Thread Sided-Coded Cryogenic Vials
1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP