96/48 Channel Automatic Capper/Decapper for Removing Caps off From Vials

Product Details
Certification: CE, ISO
Product: 96/48 Channel Automatic Capper/Decapper
Thread Type: External Thread
Still deciding? Get samples of US$ 120000/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • 96/48 Channel Automatic Capper/Decapper for Removing Caps off From Vials
  • 96/48 Channel Automatic Capper/Decapper for Removing Caps off From Vials
  • 96/48 Channel Automatic Capper/Decapper for Removing Caps off From Vials
  • 96/48 Channel Automatic Capper/Decapper for Removing Caps off From Vials
  • 96/48 Channel Automatic Capper/Decapper for Removing Caps off From Vials
  • 96/48 Channel Automatic Capper/Decapper for Removing Caps off From Vials
Find Similar Products

Basic Info.

Model NO.
CKS-5096/CKS-5048
Dimensions(mm)
323*223*395
Rated Voltage
220V
Maximum Power Consumption
160W
Decapping Time /Capping Time
<20s
Transport Package
Case
Specification
1 Piece/Case
Trademark
Biologix
Origin
Changzhou, Jiangsu, China

Product Description

96/48 Channel Automatic Capper/Decapper for Removing Caps Off From Vials

Feature:
·Simultaneously capping/decapping cryogenic vials in a 96/48-well rack within 10 to 20 seconds

·Touch screen and navigation design for easy operation

·Drawer-type input/output ports reduce risk of contamination

·Compact modular design, can be placed on the desktop to form an automated work line with other equipment

·Precise torque ensures the optimal opening and closing position of the cap, reducing component wear

·The 96-channel capper is suitable for the Biologix external thread 96-well SBS cryogenic vial racks, which is compatible with 0.4ml, 0.75ml, 1.4ml and other capacities.

·The 48-channel capper is suitable for the Biologix external thread 48-well SBS cryogenic vial racks, and can be compatible with 1.0ml, 2.0ml, 5.0ml and other capacities.

·Customized services can be provided according to needs.
96/48 Channel Automatic Capper/Decapper for Removing Caps off From Vials
96/48 Channel Automatic Capper/Decapper for Removing Caps off From Vials

Ordering Information
Cat # Product Thread Type Dimensions(mm) Rated voltage Maximum power
consumption
Decapping time
/Capping time
CKS-5096 96 Channel Automatic
Capper/Decapper
External thread 323*223*395 220V 160W <20S
CKS-5048 48 Channel Automatic
Capper/Decapper
External thread 323*223*395 220V 160W <20S

96/48 Channel Automatic Capper/Decapper for Removing Caps off From Vials1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier