5.0 Ml Cryogenic Vial External Thread Tube with Side Barcode

Product Details
Warranty: 5 Years
Disposable: Disposable
Certification: CE, ISO, ISO9001
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • 5.0 Ml Cryogenic Vial External Thread Tube with Side Barcode
  • 5.0 Ml Cryogenic Vial External Thread Tube with Side Barcode
  • 5.0 Ml Cryogenic Vial External Thread Tube with Side Barcode
  • 5.0 Ml Cryogenic Vial External Thread Tube with Side Barcode
  • 5.0 Ml Cryogenic Vial External Thread Tube with Side Barcode
Find Similar Products

Basic Info.

Material
PP
Bottle Top
Screw Top
Capacity
5ml
Screw Threads
External, Internal
Design
Black Graduation and White Writing Area
Sterile
Gamma Radiations Sterilized
Temperature
-196c to 121c
Other
Rnase and Dnase Free, Endotoxin, Foreign DNA Free
Color
White, Red, Yellow, Blue, Green, Violet and Clear
Rnase&Dnase Free
Yes
Non-Pyrogenic
Yes
Side Barcode
Yes
Transport Package
100 /Bag, 30 Bags/Case
Specification
5ml
Trademark
CryoKING
Origin
Changzhou, Jiangsu
Production Capacity
2000cases/Month

Product Description

5.0 ML Cryogenic Vial External Thread  Tube with Side Barcode 
5.0 Ml Cryogenic Vial External Thread Tube with Side Barcode
5.0 Ml Cryogenic Vial External Thread Tube with Side Barcode

 
5.0 Ml Cryogenic Vial External Thread Tube with Side Barcode
5.0 Ml Cryogenic Vial External Thread Tube with Side Barcode

Features:

1. Material: Strong, medical-grade polypropylene, and can be repeatedly frozen and thawed

2. Gamma-sterile

3. Autoclavable to 121°C and freezable to -196°C, and can be stored in vapor phase liquid nitrogen

4. Universal screw threads, sealing ring cap

    5. Fit cryogenic vials with either internal or external screw threads for quick and convenient classification and                 visual  identification

    6. 7 colors: white, red, yellow, blue, greenviolet and Clear


Ordering Information
88-6500 5.0 ml vial, white cap, External Thread,with side barcode, PP, No O-ring, 25 Pieces/Bag, 10 Bags/Pack, 4 Packs/Case
88-6501 5.0 ml vial, red cap, External Thread,with side barcode, PP, No O-ring, 25 Pieces/Bag, 10 Bags/Pack, 4 Packs/Case
88-6502 5.0 ml vial, green cap, External Thread,with side barcode, PP, No O-ring, 25 Pieces/Bag, 10 Bags/Pack, 4 Packs/Case
88-6503 5.0 ml vial, blue cap, External Thread,with side barcode, PP, No O-ring, 25 Pieces/Bag, 10 Bags/Pack, 4 Packs/Case
88-6504 5.0 ml vial, yellow cap, External Thread,with side barcode, PP, No O-ring, 25 Pieces/Bag, 10 Bags/Pack, 4 Packs/Case
88-6505 5.0 ml vial, purple cap, External Thread,with side barcode, PP, No O-ring, 25 Pieces/Bag, 10 Bags/Pack, 4 Packs/Case
 

*Call for information cryogenic vials
 

5.0 Ml Cryogenic Vial External Thread Tube with Side Barcode

 


1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier