Laboratory Consumable Graded 0.2/0.45um Membrane Atcc19146, Gamma Sterilized Pes Syrings Filter

Product Details
Disposable: Disposable
Certification: CE, ISO, FDA
Material: Pes Ca
Still deciding? Get samples of US$ 0/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP
  • Laboratory Consumable Graded 0.2/0.45um Membrane Atcc19146, Gamma Sterilized Pes Syrings Filter
  • Laboratory Consumable Graded 0.2/0.45um Membrane Atcc19146, Gamma Sterilized Pes Syrings Filter
  • Laboratory Consumable Graded 0.2/0.45um Membrane Atcc19146, Gamma Sterilized Pes Syrings Filter
  • Laboratory Consumable Graded 0.2/0.45um Membrane Atcc19146, Gamma Sterilized Pes Syrings Filter
  • Laboratory Consumable Graded 0.2/0.45um Membrane Atcc19146, Gamma Sterilized Pes Syrings Filter
  • Laboratory Consumable Graded 0.2/0.45um Membrane Atcc19146, Gamma Sterilized Pes Syrings Filter
Find Similar Products

Basic Info.

Model NO.
08-PES1322R/08-PES2522R
Pore Size
0.22um 0.45um
Sterile
Yes
Package
Individually Packed
Diameter
13/25/30/33mm
Lure Lock
Double Lure Lock
Unit
100/Pack, 4 Packs/Case
Trademark
BIOLOGIX
Origin
Changzhou Jiangsu China

Packaging & Delivery

Package Size
18.00cm * 8.00cm * 11.00cm
Package Gross Weight
3.000kg

Product Description

Laboratory Sterile Graded 0.2/0.45um Membrane Atcc19146, Gamma Sterilized PES Syrings Filter
Feature:

Syringe Filters Membrane PES Pore Size 0.22um 0.45um Extreme-low Protein Binding ·

· Syringe filters are suitable for 1ml~150ml liquid or solution, vacuum units are suitable for 150ml~2L liquid or solution
· Single Use and Gamma Ray pre-sterilized
· Non-pyrogenic, low extractables and surfactant-free ensures purity of filtrate.
· Extreme-low Protein Binding <1.5% (PES)
· Excellent Throughput, for faster filtration and more process volume.

 

Laboratory Consumable Graded 0.2/0.45um Membrane Atcc19146, Gamma Sterilized Pes Syrings Filter
Laboratory Consumable Graded 0.2/0.45um Membrane Atcc19146, Gamma Sterilized Pes Syrings Filter
Ordering Information
Cat # Membrane Pore Size(μm) Description Individually Packed Unit
08-PES1322R PES 0.22 Diameter:13mm. Female luer lock + male luer slip. Yes 100 Pieces/Pack, 800 Pieces/Case
08-PES2522R PES 0.22 Diameter:25mm. Female luer lock + male luer slip. Yes 100 Pieces/Pack, 400 Pieces/Case
08-PES3022R PES 0.22 Diameter:30mm. Female luer lock + male luer slip. Yes 100 Pieces/Pack, 400 Pieces/Case
08-PES3322S PES 0.22 Diameter:33mm. Double luer lock. Yes 100 Pieces/Pack, 400 Pieces/Case
08-PES3345S PES 0.45 Pore size: 0.45μm, diameter:33mm. Double luer lock. Yes 100 Pieces/Pack, 400 Pieces/Case
08-PES3322M PES 0.22 Diameter:33mm. Female luer lock + male luer slip. Yes 100 Pieces/Pack, 400 Pieces/Case
08-PES3345M PES 0.45 Diameter:33mm. Female luer lock + male luer slip. Yes 100 Pieces/Pack, 400 Pieces/Case
08-CA3022R CA 0.22 Diameter:30mm. Female luer lock + male luer slip. Yes 100 Pieces/Pack, 400 Pieces/Case
08-CA3045R CA 0.45 Diameter:30mm. Female luer lock + male luer slip. Yes 100 Pieces/Pack, 400 Pieces/Case

Laboratory Consumable Graded 0.2/0.45um Membrane Atcc19146, Gamma Sterilized Pes Syrings Filter1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier